There are many ways how you can create a server to which Modbus will send data to. In this example we are going to be using Windows 10 computer and Hercules app, which you can download  [https://www.hw-group.com/product-version/hercules here], to create a test server. Download, install the app and apply the configuration below:
 
There are many ways how you can create a server to which Modbus will send data to. In this example we are going to be using Windows 10 computer and Hercules app, which you can download  [https://www.hw-group.com/product-version/hercules here], to create a test server. Download, install the app and apply the configuration below:
   −
[[File:Networking_rut955_configuration_modbus_serial_8_v1.png|border|class=tlt-border]]
+
[[File:Modbus serial rut955 5.png|border|class=tlt-border]]
    
# Select '''TCP Server''' tab.
 
# Select '''TCP Server''' tab.
# Enter '''Port''' (In this example default 1883 is used).
+
# Enter '''Port''' (In this example default 80 is used).
 
# Click '''Listen'''
 
# Click '''Listen'''
   Line 94: Line 94:  
----
 
----
   −
In order to setup your router to send Modbus data to server you will need to navigate to '''Services > Modbus > Modbus Data to Server'''.
+
In order to setup your router to send Modbus data to server you will need to navigate to '''Services > Data to Server''' and press '''ADD''' to add a new instance.
   −
[[File:Networking_rut955_configuration_modbus_serial_9_v1.png|border|class=tlt-border]]
+
[[File:Modbus serial rut955 6.png|border|class=tlt-border|1100x700px]]
    +
[[File:Modbus serial rut955 7.png|border|class=tlt-border|1100x700px]]
 +
 +
# Enable instance.
 +
# Write name.
 +
# Select data source (Modbus).
 
# Select '''Protocol''' (In this example HTTP(S) will be used).
 
# Select '''Protocol''' (In this example HTTP(S) will be used).
 +
# Enter desired JSON format.
 
# Enter '''IP''' and '''port''' of the PC with the Hercules software.
 
# Enter '''IP''' and '''port''' of the PC with the Hercules software.
# Enter '''Period''' (minutes, how often router should send data to server).
+
# Click '''Save'''.
# Click '''ADD'''.
     −
Then you will be redirected to '''Advanced sender settings'''.
+
[[File:Modbus serial rut955 8.png|border|class=tlt-border|1100x700px]]
 
  −
[[File:Networking_rut955_configuration_modbus_serial_10_v1.png|border|class=tlt-border]]
  −
 
  −
# Enter '''Name''' (It can be anything you want).
  −
# Click '''Save'''.
      
===Receiving data===
 
===Receiving data===
Line 115: Line 115:  
Open Hercules again, press '''Listen''' and you should start receiving Modbus Data messages.
 
Open Hercules again, press '''Listen''' and you should start receiving Modbus Data messages.
   −
[[File:Networking_rut955_configuration_modbus_serial_11_v1.png|border|class=tlt-border]]
+
[[File:Modbus serial rut955 9.png|border|class=tlt-border|700x700px]]
    
Try to change some data in the Modbus Slave simulator.
 
Try to change some data in the Modbus Slave simulator.
   −
[[File:Networking_rut955_configuration_modbus_serial_12_v1.png|border|class=tlt-border]]
+
[[File:Modbus serial rut955 10.png|border|class=tlt-border|700x700px]]
    
Received data should change.
 
Received data should change.
   −
[[File:Networking_rut955_configuration_modbus_serial_13_v1.png|border|class=tlt-border]]
+
[[File:Modbus serial rut955 11.png|border|class=tlt-border]]
    
==Slave alarms==
 
==Slave alarms==