Difference between revisions of "TSW010 Power Consumption"

From Teltonika Networks Wiki
(Created page with "TSW010 power consumption values in different states of operation are represented in the table(s) below:<br><br> <table class="nd-othertables_3"> <tr style="font-weight:bol...")
 
 
Line 1: Line 1:
TSW010 power consumption values in different states of operation are represented in the table(s) below:<br><br>
+
'''Averaged''' TSW010 power consumption values in different states of operation are represented in the table(s) below:<br><br>
 
<table class="nd-othertables_3">
 
<table class="nd-othertables_3">
 
     <tr style="font-weight:bold">
 
     <tr style="font-weight:bold">

Latest revision as of 10:48, 16 August 2024

Main Page > TSW Switches > TSW010 > TSW010 Manual > TSW010 Power Consumption

Averaged TSW010 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
25
0.23
Idle (24 V)
21
0.26
Idle (24 V)
14
0.33


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
49
0.45
2 LAN devices connected + heavy data traffic1 (12 V)
39
0.47
2 LAN devices connected + heavy data traffic1 (24 V)
24
0.58


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
78
0.70
5 LAN devices connected + heavy data traffic1 (12 V)
61
0.73
5 LAN devices connected + heavy data traffic1 (24 V)
37
0.89


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.