<h3>Simultaneous powering</h3>
 
<h3>Simultaneous powering</h3>
 
----
 
----
The device can be powered from the power socket and over Ethernet simultaneously. The power socket has higher priority meaning that the device will draw power from the power socket as long as it is available.
+
The device can be powered from the power socket and over Ethernet simultaneously.
 +
<b>If device batch number is between 1 and 11, both PSUs should have similar output voltages. Meanwhile, devices manufactured from batch number 12 can have different voltage PSUs connected to its power socket and Ethernet port.</b>
    +
The power socket has higher priority meaning that the device will draw power from the power socket as long as it is available.
 
When the device is switching from one power source to another it loses power for a fraction of a second and may reboot. The device will function correctly after the reboot.|}}
 