RUT260 OPC UA Server: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
Line 1: Line 1:
{{Template:Networking_rutos_manual_opcua_server
{{Template:Networking_rutos_manual_opcua_server
<!------------------------DEVICE----------------------->
<!------------------------DEVICE----------------------->
| name  = RUT260
| name  = RUT260
| series = RUT2M
| series = RUT2M
<!----------------------SEPARATORS--------------------->
<!----------------------SEPARATORS--------------------->
| digitalio      = 1 <!----------------------Digital inputoutput.--------------------->
| digitalio      = 1 <!----------------------Digital inputoutput.--------------------->
| configurableio = 0 <!----------------------Configurable inputoutput.--------------------->
| configurableio = 0 <!----------------------Configurable inputoutput.--------------------->
| relay          = 0
| relay          = 0
| adc            = 0
| adc            = 0
| gps            = 0
| gps            = 0
| mobile        = 1
| mobile        = 1
}}
}}

Revision as of 16:10, 18 December 2023

Main Page > RUT Routers > RUT260 > RUT260 Manual > RUT260 WebUI > RUT260 Services section > RUT260 OPC UA Server

The information in this page is updated in accordance with firmware version RUT2M_R_00.07.10.4.

Summary

OPC Unified Architecture (OPC UA) is a cross-platform, open-source, IEC62541 standard for data exchange from sensors to cloud applications developed by the OPC Foundation. The UA in OPC UA stands for “Unified Architecture” and refers to the latest specification of the standard. It differs from its predecessor in that it is platform-independent, moving away from COM/DCOM to purely binary TCP/IP or alternatively SOAP.


This manual page provides an overview of the OPC UA Server in RUT260 devices.

Note: OPC UA Server is additional software that can be installed from the System → Package Manager page.

Status

This section displays OPC UA Server status information.

OPC UA Server Configuration

The OPC UA Server Configuration section is used to enable the local OPC UA server.

Field Value Description
Enable off | on; default: off Enables OPC UA server.
Port integer [1..65535]; default: none Service port.


OPC UA Server variables

All RUTOS device variables are described in the table below:

Note: All the variables have these qualities in common:

  • Namespace index is 1
  • Node ID type is string
  • Read-only
  • Updated upon request
ID Type Description
sys_uptime UINT32 System uptime in seconds.
sys_serial String Device serial number.
sys_devname String Device name.
sys_devcode String Device code.
sys_version String Firmware version.
sys_hostname String Hostname.
lan_mac String LAN MAC address.
lan_ip String IP address of LAN interface.
lan_mask String Subnet mask of LAN interface.
lan_gateway String Gateway IP address of LAN interface.
lan_dns Array of String IP addresses of LAN interface DNS servers.
rut_wan_ip String IP address if WAN is connected.
rut_wan_type String Values of WAN type.
io_din Array of BOOL Values of digital input pins.
io_dout Array of BOOL Values of digital output pins.
mob_modem_count UINT32 Modem count.
mob_modem_imei Array of String Modem IMEI.
mob_modem_serial Array of String Modem serial number.
mob_modem_mnf Array of String Modem manufacturer name.
mob_modem_model Array of String Modem model name.
mob_modem_fw Array of String Modem firmware version string.
mob_modem_temp Array of FLOAT Modem temperature.
mob_sim_count Array of UINT32 SIM count.
mob_sim Array of UINT32 Selected SIM.
mob_sim_state Array of String SIM state.
mob_sim_iccid Array of String SIM ICCID.
mob_rssi Array of INT32 RSSI.
mob_conn_type Array of String Data carrier type.
mob_conn_state Array of String Connection state.
mob_net_state Array of String Network link state.
mob_operator Array of String Operator name.