Template:PCN RutOS 7.7: Difference between revisions

From Teltonika Networks Wiki
(Created page with "==2024.02.16: PoE Alternative change== Starting from 2024 Q2, TSW101 switch will be produced with PoE alternative A instead of alternative B. {| class="wikitable" |- | style...")
 
Line 1: Line 1:
==2024.02.16: PoE Alternative change==
==2024.02.16: PoE Alternative change==


Starting from 2024 Q2, TSW101 switch will be produced with PoE alternative A instead of alternative B.
With the release of RutOS version 7.7, XXX device will experience changes related to the security of the device.


{| class="wikitable"
{| class="wikitable"
Line 14: Line 14:
|-
|-
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" |Hardware change
| style="text-align: left; background: white;" |Firmware change
|-
|-
| style="width: 221px; text-align: left; background: white;" | Detailed description
| style="width: 221px; text-align: left; background: white;" | Detailed description
| style="width: 908px; text-align: left; background: white;" | In order to ensure better compatibility with other devices, starting from 2024 Q2, TSW101 switch will be produced with PoE alternative A.<br>
| style="width: 908px; text-align: left; background: white;" | Previously, when resetting devices, logs, and SIM PIN settings were not reset. However, with Firmware Version 7.7, all devices will reset logs and SIM PIN settings to factory defaults when using the reset button. It's important to note that this change only affects resets initiated using the reset button. Other reset methods, such as WebUI, SMS, and others, will remain unaffected.<br>
|-
|-
| style="text-align: left; background: white;" | Change reasons
| style="text-align: left; background: white;" | Change reasons
| style="text-align: left; background: white;" | Increasing compitability.
| style="text-align: left; background: white;" | Increasing security.
|-
|-
|}
|}
Line 32: Line 32:
| style="width: 448px; text-align: left; background: white;" | Order code changes
| style="width: 448px; text-align: left; background: white;" | Order code changes
|-
|-
| style="text-align: left; background: white;" | TSW101
| style="text-align: left; background: white;" | XXXXXX
| style="text-align: left; background: white;" | TSW101 *****
| style="text-align: left; background: white;" | XXXXXX *****
| style="text-align: left; background: white;" | No changes
| style="text-align: left; background: white;" | No changes
|-
|-
| style="text-align: left; background: white;" | Upcoming change date
| style="text-align: left; background: white;" | Upcoming change date
| style="text-align: left; background: white;" colspan="2" | 2024 Q2
| style="text-align: left; background: white;" colspan="2" | 2024 Q2, with the release  of RutOS 7.7
|-
|-
|}
|}
Line 47: Line 47:
| style="width: 221px; text-align: left; background: white;" | Risk assessment
| style="width: 221px; text-align: left; background: white;" | Risk assessment
| style="width: 908px; text-align: left; background: white;" colspan="2"|  
| style="width: 908px; text-align: left; background: white;" colspan="2"|  
Devices that exclusively rely only on PoE alternative B will no longer maintain compatibility with the TSW101 switch.
??
|-
|-
| style="text-align: left; background: white;" | Suggested implementation plan
| style="text-align: left; background: white;" | Suggested implementation plan

Revision as of 16:59, 7 February 2024

2024.02.16: PoE Alternative change

With the release of RutOS version 7.7, XXX device will experience changes related to the security of the device.

PCN Number: PCN_TSW101_2024_02_16_EN
Change description
Change type Firmware change
Detailed description Previously, when resetting devices, logs, and SIM PIN settings were not reset. However, with Firmware Version 7.7, all devices will reset logs and SIM PIN settings to factory defaults when using the reset button. It's important to note that this change only affects resets initiated using the reset button. Other reset methods, such as WebUI, SMS, and others, will remain unaffected.
Change reasons Increasing security.
Affected products information
Model Affected order codes Order code changes
XXXXXX XXXXXX ***** No changes
Upcoming change date 2024 Q2, with the release of RutOS 7.7
Change impact
Risk assessment

??

Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.