RUT142 Power Consumption: Difference between revisions

From Teltonika Networks Wiki
m (Vainius.l moved page Draft:RUT142 Power Consumption to RUT142 Power Consumption without leaving a redirect)
No edit summary
Line 75: Line 75:
<small><sup><small>2</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br>
<small><sup><small>2</small></sup> - Load created using ''md5sum'' (calculation and verification of 128-bit MD5 hashes). </small> <br>
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small>
<small>Power consumption may differ due to mobile data transmission speed, testing environment and conditions.</small>
[[Category:RUT142_Manual]]

Revision as of 13:28, 9 April 2024

Main Page > RUT Routers > RUT142 > RUT142 Manual > RUT142 Power Consumption

RUT142 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
95
0.86
Idle (12 V)
73
0.88
Idle (24 V)
43
1.03


Test type
Current (mA)
Power consumption (W)
1 LAN devices connected 1 (9 V)
115
1.04
1 LAN devices connected 1 (12 V)
89
1.07
1 LAN devices connected 1 (24 V)
49
1.18


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi, device connected to RS232 (9 V)
150
1.35
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi, device connected to RS232 (12 V)
115
1.38
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi, device connected to RS232 (24 V)
64
1.54


1 - Data streams between RUT142 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.