RUT140 Power Consumption: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
 
Line 1: Line 1:
RUT140 power consumption values in different states of operation are represented in the table(s) below:<br>
'''Averaged''' RUT140 power consumption values in different states of operation are represented in the table(s) below:<br>
<table class="nd-othertables_3">
<table class="nd-othertables_3">
     <tr style="font-weight:bold">
     <tr style="font-weight:bold">

Latest revision as of 09:37, 16 August 2024

Main Page > RUT Routers > RUT140 > RUT140 Manual > RUT140 Power Consumption

Averaged RUT140 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
88
0.79
Idle (12 V)
67
0.80
Idle (24 V)
40
0.96


Test type
Current (mA)
Power consumption (W)
1 LAN devices connected 1 (9 V)
113
1.02
1 LAN devices connected 1 (12 V)
87
1.04
1 LAN devices connected 1 (24 V)
49
1.18


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (9 V)
133
1.2
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (12 V)
103
1.27
2 LAN devices connected 1 + high CPU load 2 + data transfer via WiFi (24 V)
58
1.39


1 - Data streams between RUT140 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.