Difference between revisions of "Template:Networking trb16 manual input output status"
From Teltonika Networks Wiki
(Created page with "<pre> ioman.gpio.dio0 ioman.gpio.dio1 </pre> In order to read values, call command <b>ubus call <i>value</i> status </b>: root@Teltonika-{{{name}}}:~# ubus call ioman.gpio....") |
|||
Line 1: | Line 1: | ||
<pre> | <pre> | ||
+ | ioman.adc.pwr0 | ||
ioman.gpio.dio0 | ioman.gpio.dio0 | ||
ioman.gpio.dio1 | ioman.gpio.dio1 | ||
Line 25: | Line 26: | ||
</ul> | </ul> | ||
− | To change input settings, use the <i><b>update</ | + | To change input settings, use the <i><b>update</b></i> command and specify a value: |
ubus call ioman.gpio.dio0 update '{"value":"0"}' | ubus call ioman.gpio.dio0 update '{"value":"0"}' |
Latest revision as of 12:11, 4 September 2024
ioman.adc.pwr0 ioman.gpio.dio0 ioman.gpio.dio1
In order to read values, call command ubus call value status :
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio1 status { "value": "0", "direction": "in", "bi_dir": false, "invert_input": false }
- dio0 is configurable input / output:
- "value": "0" means low level state.
- "value": "1" means high level state.
- "direction": "in" means input state.
- "direction": "out" means output state.
To change input settings, use the update command and specify a value:
ubus call ioman.gpio.dio0 update '{"value":"0"}' ubus call ioman.gpio.dio0 update '{"value":"1"}' ubus call ioman.gpio.dio0 update '{"direction":"in"}' ubus call ioman.gpio.dio0 update '{"direction":"out"}'