(Created page with "{{Template: Networking_device_manual_remote_management | name = RUTM59 | series = RUTM | mobile = 1 | sms = 1 | json = 1 | vpn = 1 | snmp = 1 | set_snmp = 0 | modbus = 1 | set_modbus = 1 | mqtt = 1 | set_mqtt = 0 | tr069 = 1 | set_tr069 = 1 | dnp3 = 1 | set_dnp3 = 0 | opcua = 1 | set_opcua = 0 | bacnet = 1 }}") |
No edit summary |
||
Line 18: | Line 18: | ||
| opcua = 1 | | opcua = 1 | ||
| set_opcua = 0 | | set_opcua = 0 | ||
| bacnet = | | bacnet = 0 | ||
}} | }} |
Revision as of 13:31, 13 December 2024
Main Page > RUTM Routers > RUTM59 > RUTM59 Manual > RUTM59 Remote Monitoring & AdministrationRUTM59 supports multiple monitoring and administration possibilities.
Remote control options
The RUTM59 router supports the following remote control capabilities:
Remote control method | Can get parameters | Can set parameters |
---|---|---|
RMS | ||
SSH | ||
HTTP | ||
SMS | ||
JSON | ||
VPN | ||
SNMP | ||
Modbus | ||
MQTT | ||
TR-069 | ||
DNP3 | ||
OPC UA |
RMS
The Remote Management System (RMS) is designed to conveniently monitor and manage all your Teltonika networking devices. The system allows to securely gather status information of your devices and to change their configuration even if the devices do not have public IP addresses.
RMS access can be configured from the System → Administration → RMS page.
Public IP
If you're using a SIM card that has a Public IP address (refer here for more information), you can reach the router via HTTP or SSH via its WAN IP address.
HTTP access
Remote HTTP access can be set up via the System → Administration → Access Control page.
SSH access
Remote SSH access can be set up via the System → Administration → Access Control page.
SMS
The router can be controlled via SMS messages using SMS utilities rules. SMS can be configured via the Services → SMS Utilities → SMS Rules page.
JSON-RPC
JSON-RPC access can be set up via the System → Administration → Access Control page. Note: As of RUTOS firmware version 7.0 and higher, it is enabled by default.
VPN
Virtual Private Networks (VPNs) provide multiple flexible options on setting up remote access to the router and its LAN network. For more information on different types of VPNs supported by RUTM59, visit the VPN manual page.
SNMP
Simple Network Management Protocol (SNMP) is a protocol for network management, used for collecting information from network devices. For more information on SNMP in RUTM59, visit the SNMP manual page.
Modbus TCP
Modbus is a serial communications protocol used in communication with various types of industrial electronic devices. For more information on Modbus TCP in RUTM59, visit the Modbus manual page.
MQTT
MQTT (MQ Telemetry Transport or Message Queue Telemetry Transport) is a publish-subscribe-based "lightweight" messaging protocol for use on top of the TCP/IP protocol. For more information on MQTT in RUTM59, visit the MQTT manual page
TR-069
Technical Report 069 (TR-069) is a technical specification of the Broadband Forum that defines an application layer protocol for remote management of customer-premises equipment (CPE) connected to an Internet Protocol (IP) network. For more information on TR-069 in RUTM59, visit the TR-069 manual page
DNP3
Distributed Network Protocol 3 (DNP3) is a set of communications protocols used between components in process automation systems. For more information on DNP3 in RUTM59, visit the DNP3 manual page
OPC UA
OPC Unified Architecture (OPC UA) is a cross-platform, open-source, IEC62541 standard for data exchange from sensors to cloud applications developed by the OPC Foundation. For more information on OPC UA in RUTM59, visit the OPC UA manual page