First lets look over how MQTT works on RUT routers. An MQTT connection takes place between two Clients and a Broker. A RUT router can be Broker, a Client or both. The MQTT Publisher (Client) present in RUT routers subscribes to two topics by default: '''router/get''' and '''get/<SERIAL>/command''', where '''<SERIAL>''' is the router's serial number. | First lets look over how MQTT works on RUT routers. An MQTT connection takes place between two Clients and a Broker. A RUT router can be Broker, a Client or both. The MQTT Publisher (Client) present in RUT routers subscribes to two topics by default: '''router/get''' and '''get/<SERIAL>/command''', where '''<SERIAL>''' is the router's serial number. When a third party client connects to the Broker, it sends the message '''id''' to the the topic '''router/get'''. The publisher then sends a response containing its serial number to the topic '''router/id'''. Now that the Client knows the router's serial number it can ask for values of various parameters by sending requests to the topic '''router/<SERIAL>/parameter_name'''. The MQTT Publisher can send responses containing values of these system parameters: | ||
{| class="wikitable" | {| class="wikitable" | ||
|+ | |+ | ||
! style="width: 250px; background: black; color: white;" | | ! style="width: 250px; background: black; color: white;" | Parameter name | ||
! style="width: 250px; background: black; color: white;" | | ! style="width: 250px; background: black; color: white;" | Parameter description | ||
|- | |- | ||
! style="text-align: left; vertical-align: top;" | | ! style="text-align: left; vertical-align: top;" | temperature | ||
| style="text-align: left; vertical-align: top;" | | | style="text-align: left; vertical-align: top;" | Temperature of the module in 0.1 degrees Celsius | ||
|- | |- | ||
! style="text-align: left; vertical-align: top;" | | ! style="text-align: left; vertical-align: top;" | operator | ||
| style="text-align: left; vertical-align: top;" | | | style="text-align: left; vertical-align: top;" | Current operator’s name | ||
|- | |- | ||
! style="text-align: left; vertical-align: top;" | | ! style="text-align: left; vertical-align: top;" | signal | ||
| style="text-align: left; vertical-align: top;" | | | style="text-align: left; vertical-align: top;" | Signal strength in dBm | ||
| style="text-align: left; vertical-align: top;" | | |- | ||
! style="text-align: left; vertical-align: top;" | network | |||
| style="text-align: left; vertical-align: top;" | Current network type (2G, 3G, 4G) | |||
|- | |||
! style="text-align: left; vertical-align: top;" | connection | |||
| style="text-align: left; vertical-align: top;" | Data connection status | |||
|- | |||
! style="text-align: left; vertical-align: top;" | wan | |||
| style="text-align: left; vertical-align: top;" | WAN IP address | |||
|- | |||
! style="text-align: left; vertical-align: top;" | uptime | |||
| style="text-align: left; vertical-align: top;" | System uptime in seconds | |||
|- | |||
! style="text-align: left; vertical-align: top;" | name | |||
| style="text-align: left; vertical-align: top;" | Router’s name | |||
|- | |||
! style="text-align: left; vertical-align: top;" | digital1 | |||
| style="text-align: left; vertical-align: top;" | Value of digital input no. 1 | |||
|- | |||
! style="text-align: left; vertical-align: top;" | digital2 | |||
| style="text-align: left; vertical-align: top;" | Value of digital input no. 2 | |||
|- | |||
! style="text-align: left; vertical-align: top;" | analog | |||
| style="text-align: left; vertical-align: top;" | Value of analog | |||
|- | |- | ||
|} | |} |
Revision as of 13:36, 30 November 2017
Main Page > General Information > Configuration Examples > Router control and monitoring > Monitoring via MQTTSummary
MQTT (MQ Telemetry Transport or Message Queue Telemetry Transport) is an ISO standard (ISO/IEC PRF 20922) publish-subscribe-based messaging protocol. It works on top of the TCP/IP protocol. It is designed for connections with remote locations where a "small code footprint" is required or the network bandwidth is limited. The publish-subscribe messaging pattern requires a message broker. This chapter is a guide on how to configure a basic MQTT setup on RUT routers.
How MQTT works
First lets look over how MQTT works on RUT routers. An MQTT connection takes place between two Clients and a Broker. A RUT router can be Broker, a Client or both. The MQTT Publisher (Client) present in RUT routers subscribes to two topics by default: router/get and get/<SERIAL>/command, where <SERIAL> is the router's serial number. When a third party client connects to the Broker, it sends the message id to the the topic router/get. The publisher then sends a response containing its serial number to the topic router/id. Now that the Client knows the router's serial number it can ask for values of various parameters by sending requests to the topic router/<SERIAL>/parameter_name. The MQTT Publisher can send responses containing values of these system parameters:
Parameter name | Parameter description |
---|---|
temperature | Temperature of the module in 0.1 degrees Celsius |
operator | Current operator’s name |
signal | Signal strength in dBm |
network | Current network type (2G, 3G, 4G) |
connection | Data connection status |
wan | WAN IP address |
uptime | System uptime in seconds |
name | Router’s name |
digital1 | Value of digital input no. 1 |
digital2 | Value of digital input no. 2 |
analog | Value of analog |