RUT240 Input/Output: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
Line 19: Line 19:
| file_output_scheduler = Networking_rut2xx_manual_input_output_output_scheduler_v1.png
| file_output_scheduler = Networking_rut2xx_manual_input_output_output_scheduler_v1.png
}}
}}
==Output==
The '''Output''' section is used to configure the router's outputs.
===Output Configuration===
----
The '''Output Configuration''' tab is used to change the default state of outputs.
[[Image:Services inputoutput output configuration rut240.PNG]]
<table class="nd-mantable">
    <tr>
        <th>field name</th>
      <th>value</th>
      <th>description</th>
    </tr>
    <tr>
      <td>Open collector output</td>
      <td>High level | Low level; Default: '''Low level'''</td>
      <td>OC Output state</td>
    </tr>
</table>
===ON/OFF===
----
The '''ON/OFF''' section is used to turn the Output ON or OFF, but it doesn't save the state permanently, meaning that after a reboot the states will revert back to their default values.
[[Image:Services inputoutput output onoff rut240.PNG]]
===Post/Get Configuration===
===Post/Get Configuration===
----
----

Revision as of 13:21, 29 July 2019

Main Page > EOL Products > RUT240 > RUT240 Manual > RUT240 WebUI > RUT240 Services section > RUT240 Input/Output

Template:Networking rutxxx manual input output

Post/Get Configuration


field name value description
Enable yes | no; Default: no Toggles Output POST/GET function ON or OFF
Username string Default: " " POST/GET service user name
Password string Default: " " POST/GET service user passwor

Periodic Control


Periodic control allows you to set up Output control rules.


field name value description
Enable yes | no; Default: no Toggles the rule ON or OFF
Output Digital OC output; Default: Digital OC output To which output the rule pertains
Action On | Off; Default: On Periodic action to be taken
Action timeout On | Off; Default: On Activates action timeout. Action timeout specifies whether an action should end after some time. For example, if the specified Action is to turn Digital OC output On and the action triggers, the Action timeout then turns Digital OC output back off after a specified amount of time in seconds specified in this field
Timeout (sec) integer; Default: " " Specifies how long the Action timeout is
Mode Fixed | Interval; Default: Fixed Fixed mode triggers the specified action on a specified day(s), hour and minute. For example, every Sunday at 8:30 AM
Interval provides you with the possibility to set up an interval after which the same action takes place

Scheduler


Scheduler lets you configure a schedule of when the Output is to be enabled or disabled.


Additional Information

Hardware Application Examples: