TRB142 Powering Options: Difference between revisions

From Teltonika Networks Wiki
No edit summary
No edit summary
 
Line 1: Line 1:
{{Template: networking_trb1_manual_powering_options
{{Template: networking_trb_manual_powering_options
<!------------------------DEVICE----------------------->
<!------------------------DEVICE----------------------->
| name  = TRB142
| name  = TRB142
| series = TRB14x
| series = TRB1
<!----------------------SEPARATORS--------------------->
<!----------------------SEPARATORS--------------------->
| eth    = 0
| eth    = 0         <!-- 1 - has Ethernet; 0 - does not have Ethernet -->
| rs485  = 0
| rs485  = 0         <!-- 1 - can be powered over RS485; 0 - cannot be powered over RS485 -->
| pin    = 4 pin    <!-- 4 pin - 4 pin connector; 16 pin - 16 pin terminal block connector -->
| psu    = 9 VDC    <!-- Standard PSU -->
| volts  = 9-30 VDC  <!-- Input voltage range -->
}}
}}

Latest revision as of 09:31, 2 September 2020

Main Page > TRB Gateways > TRB142 > TRB142 Manual > TRB142 Powering Options

This chapter contains information on powering options supported by TRB142 devices.

Power socket

The TRB142 device can be powered over the 4 pin connector using a 9-30 VDC power supply unit (PSU). Refer to the image below for the power socket pinout information:

If you decide not to use the standard 9 VDC PSU and want to power the device from a higher voltage, please make sure that you choose a power supply of high quality. Some power supplies can produce voltage peaks significantly higher than the declared output voltage, especially during connection and disconnection.

While the device is designed to accept input voltage in the range of 9-30 VDC, high voltage power supplies can harm the device. If you want to use high voltage power supplies it is recommended to also use additional safety equipment to suppress voltage peaks from the power supply.

Suggestion: If you're using a different power supply than the one included in the standard packaging, make sure it meets the same power (W) specifications as the original. Otherwise, some features of the device might not work properly. Please refer to the device's portfolio page to verify the power supply specifications: Power Consumption



Ground loops

Do not connect the power supply negative terminal of our device to the chassis or earth exclusively.

This connection could cause ground loops. For example, if the antenna shield and power supply negative terminal are connected to the chassis or earth, it forms a ground loop, therefore unwanted current could flow through a device PCB ground and may cause damage.