Template:Networking trb1 manual input output status: Difference between revisions
(Created page with " ioman.gpio.din1 ioman.gpio.dout1 Call command <b>ubus call <u>value</u> status </b>: root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dout1 status { "value": "0...") |
No edit summary |
||
Line 25: | Line 25: | ||
</li> | </li> | ||
</ul> | </ul> | ||
Revision as of 08:43, 4 November 2020
ioman.gpio.din1 ioman.gpio.dout1
Call command ubus call value status :
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dout1 status { "value": "0", "direction": "in", "bi_dir": false, "invert_input": false }
- din1 is the input:
- "value": "0" means low level state.
- "value": "1" means high level state.
- dout1 is the output:
- "value": "0" means low level state.
- "value": "1" means high level state.