Template:Networking rut36x manual input output status: Difference between revisions
(Created page with " ioman.gpio.dio0 ioman.gpio.dio1 Call command <b>ubus call <u>value</u> status </b>: root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status { "value": "0",...") |
No edit summary |
||
Line 1: | Line 1: | ||
<pre> | |||
ioman.gpio.dio0 | |||
ioman.gpio.dio1 | |||
</pre> | |||
Call command <b>ubus call <u>value</u> status </b>: | Call command <b>ubus call <u>value</u> status </b>: | ||
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status | root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status | ||
{ | { |
Revision as of 14:55, 4 November 2020
ioman.gpio.dio0 ioman.gpio.dio1
Call command ubus call value status :
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status { "value": "0", "direction": "in", "bi_dir": false, "invert_input": false }
- din1 is the input:
- "value": "0" means low level state.
- "value": "1" means high level state.
- dout1 is the output:
- "value": "0" means low level state.
- "value": "1" means high level state.