Product change notifications (PCN) is a way of informing customers of upcoming changes related to Teltonika Networks products. This includes outward appearance adjustments, hardware improvements, changes to package contents, etc. Changes related to a product's firmware are not included in PCNs (click here to see the firmware changelog).
This page stores information regarding changes to the RUT951 device. Below you will find a list of both upcoming and already implemented changes sorted by newest to oldest (top to bottom).
2023.04.17: Product packaging changes
Starting from 2023 week XX RUT951 router product packaging will be changed.
Change description
Change type
Packaging
Detailed description
The packaging for the product will undergo several updates including an update to the side print of the box. Additionally, the box will now feature press with certificates that will be printed according to the region. Finally, there will also be changes made to the company information section including the address, telephone number, email and website link.
Current design:
Updated packaging design:
Packaging dimensions will not change.
Change reasons
Design improvement.
Affected products information
Model
Affected order codes
Order code changes
RUT951
RUT951 *****
No changes
Product release date
2023 week XX
Change impact
Risk assessment
The product handling and storage process may require review. Marketing materials, such as photos, might need replacement.
Suggested implementation plan
Information included in this PCN will help adapt to the upcoming changes. For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2023.02.13: MAC address range change
All Teltonika Networks devices manufactured starting from 2023, week 9 will have additional new MAC address range.
Change description
Change type
MAC address range
Detailed description
All Teltonika Networks devices manufactured starting from 2023, week 9 may have a MAC address from the new MAC address range 20:97:27:00:00:00 - 20:97:27:FF:FF:FF, as well as the current MAC address range 00:1E:42:00:00:00 - 00:1E:42:FF:FF:FF
Change reasons
Endpoint of the previous MAC address range.
Affected products information
Model
Affected order codes
Order code changes
All Teltonika Networks devices
All order codes
No changes
Upcoming change date
2023, week 9
Change impact
Risk assessment
Device install procedures or any automated solutions might need modifications.
Suggested implementation plan
For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
To download the pdf version of this notification, click here.
2023.02.13: MAC address range change
All Teltonika Networks devices manufactured starting from 2023, week 9 will have additional new MAC address range.
Change description
Change type
MAC address range
Detailed description
All Teltonika Networks devices manufactured starting from 2023, week 9 may have a MAC address from the new MAC address range 20:97:27:00:00:00 - 20:97:27:FF:FF:FF, as well as the current MAC address range 00:1E:42:00:00:00 - 00:1E:42:FF:FF:FF
Change reasons
Endpoint of the previous MAC address range.
Affected products information
Model
Affected order codes
Order code changes
All Teltonika Networks devices
All order codes
No changes
Upcoming change date
2023, week 9
Change impact
Risk assessment
Device install procedures or any automated solutions might need modifications.
Suggested implementation plan
For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
To download the pdf version of this notification, click here.
2022.08.18: Default password change
All RUT951 devices manufactured starting from 2022, week 35, will have unique default password.
Change description
Change type
Default password change
Detailed description
RUT951 devices manufactured starting from Q3 2022 will have unique default password.
Change reasons
Increasing device security
Affected products information
Model
Affected order codes
Order code changes
RUT951
RUT951 ******
No changes
Upcoming change date
2022, week 35
Change impact
Risk assessment
Device install procedures or any automated solutions might need modifications. Please note: this product change notification does not affect any previous RUT951 devices.
Suggested implementation plan
For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2022.08.18: QSG flyer replacement
Starting from 2022, week 35, RUT951 routers will come with a new QSG flyer in the packaging.
Change description
Change type
Replacement of QSG flyer
Detailed description
RUT951 devices manufactured starting from Q3 2022 will have a new QSG flyer in the packaging. The new QSG flyer includes the short version of QSG with a QR code/link to the full Web QSG version: teltonika-networks.com/QSG_RUT951
Previous design:
New design:
The new flyer will include QR codes with URL links to RMS and the Web version of the QSG (Quick Start Guide) for the RUT951.
Change reasons
Reducing environmental impact.
Affected products information
Model
Affected order codes
Order code changes
RUT951
RUT951 ******
No changes
Upcoming change date
2022, week 35
Change impact
Risk assessment
Marketing material such as photos might need replacing.
Suggested implementation plan
Information included in this PCN will help adapt to the upcoming changes.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2022.08.18: Changes in engraving/labeling
Starting from 2022, week 35, RUT951 routers will be produced with modified bottom engraving/labeling.
Change description
Change type
External/visual
Detailed description
The device's unique default password will be added to the bottom engraving/labeling. The formatting for the remaining information on the labeling/engraving will be adjusted, and the Fira font will be used instead of Arial. The device's unique default password information will also be added to the QR code Information displayed after scanning QR code with syntax: WIFI:T:WPA;S:{{WIFISSID}};P:{{PASSWORD}};SN:{{SERIAL}};I:{{IMEI}};M:{{MAC}};U:admin;PW:{{DEVICEPASSWORD}};B:{{BATCH}};
From the device top engraving/labeling, the previously relevant authentication information text will be removed: User/Pass: admin/admin01.
The labeling on the product packaging will stay unchanged.
Old top engraving/labeling:
Old bottom engraving/labeling:
New top engraving/labeling:
New bottom engraving/labeling:
Change reasons
To accommodate the change from the standard default password to a unique default password for each device.
Affected products information
Model
Affected order codes
Order code changes
RUT951
RUT951 ******
No changes
Upcoming change date
2022, week 35
Change impact
Risk assessment
Changes to top labeling/engraving. Device's unique default password will be present on the product itself. This might impact marketing materials due to changing contents of the bottom informational engraving/labeling.
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.