TSW212 Power Consumption

From Teltonika Networks Wiki
Revision as of 12:18, 10 October 2023 by TomasG (talk | contribs)

Main Page > TSW Switches > TSW212 > TSW212 Manual > TSW212 Power Consumption
Test type
Current (mA)
Power consumption (W)
Idle (9 V)
141
1.27
Idle (12 V)
109
1.31
Idle (24 V)
57
1.37
Idle (44 V)
33
1.45
Idle (50 V)
29
1.45
Idle (57 V)
26
1.48


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
236
2.12
2 LAN devices connected + heavy data traffic1 (12 V)
179
2.15
2 LAN devices connected + heavy data traffic1 (24 V)
95
2.28
2 LAN devices connected + heavy data traffic1 (44 V)
54
2.38
2 LAN devices connected + heavy data traffic1 (50 V)
48
2.40
2 LAN devices connected + heavy data traffic1 (57 V)
43
2.45


Test type
Current (mA)
Power consumption (W)
2 SFP and 8 LAN devices connected + heavy data traffic1 (9 V)
506
4.55
2 SFP and 8 LAN devices connected + heavy data traffic1 (12 V)
379
4.55
2 SFP and 8 LAN devices connected + heavy data traffic1 (24 V)
195
4.68
2 SFP and 8 LAN devices connected + heavy data traffic1 (44 V)
111
4.88
2 SFP and 8 LAN devices connected + heavy data traffic1 (50 V)
99
4.95
2 SFP and 8 LAN devices connected + heavy data traffic1 (57 V)
88
5.02


1 - Data streams between devices were created using iPerf3.
Power consumption may differ due to testing environment and conditions.