RUT906 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle, no SIM card inserted (9 V)
111
1
Idle, no SIM card inserted (12 V)
83
1
Idle, no SIM card inserted (24 V)
43
1.03


Test type
Current (mA)
Power consumption (W)
Idle + mobile data on 1 (9 V)
99
0.89
Idle + mobile data on 1 (12 V)
75
0.9
Idle + mobile data on 1 (24 V)
39
0.94


Test type
Current (mA)
Power consumption (W)
Mobile data on 1 + 1 LAN device connected 2 (9 V)
125
1.13
Mobile data on 1 + 1 LAN device connected 2 (12 V)
91
1.09
Mobile data on 1 + 1 LAN device connected 2 (24 V)
48
1.15


Test type
Current (mA)
Power consumption (W)
Max speed LTE transmission + 4 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi (9V)
423
3.8
Max speed LTE transmission + 4 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi (12V)
318
3.82
Max speed LTE transmission + 2 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi (24V)
169
4.06


1 - Only mobile data connection established with no additional traffic.
2 - Data streams between RUT260 and other connected LAN devices created using iPerf.
3 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).