RUT301 Power Consumption

From Teltonika Networks Wiki
Revision as of 14:57, 27 February 2024 by Vainius.l (talk | contribs)

Main Page > RUT Routers > RUT301 > RUT301 Manual > RUT301 Power Consumption

RUT301 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
59
0.53
Idle (12 V)
46
0.55
Idle (24 V)
31
0.744


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected 1 (9 V)
78
0.7
2 LAN devices connected 1 (12 V)
62
0.74
2 LAN devices connected 1 (24 V)
40
0.96


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (9 V)
413
3.71
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (12 V)
305
3.66
5 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (24 V)
159
3.82


1 - Data streams between RUT300 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
3 - USB device with ~ 300 mA current draw.
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.

[[Category:{{{name}}} Manual]]