RUT200 OPC UA Server
The information in this page is updated in accordance with firmware version RUT2M_R_00.07.10.4.
Summary
OPC Unified Architecture (OPC UA) is a cross-platform, open-source, IEC62541 standard for data exchange from sensors to cloud applications developed by the OPC Foundation. The UA in OPC UA stands for “Unified Architecture” and refers to the latest specification of the standard. It differs from its predecessor in that it is platform-independent, moving away from COM/DCOM to purely binary TCP/IP or alternatively SOAP.
This manual page provides an overview of the OPC UA Server in RUT200 devices.
Note: OPC UA Server is additional software that can be installed from the System → Package Manager page.
Status
This section displays OPC UA Server status information.
OPC UA Server Configuration
The OPC UA Server Configuration section is used to enable the local OPC UA server.
Field | Value | Description |
---|---|---|
Enable | off | on; default: off | Enables OPC UA server. |
Port | integer [1..65535]; default: none | Service port. |
OPC UA Server variables
All RUTOS device variables are described in the table below:
Note: All the variables have these qualities in common:
- Namespace index is 1
- Node ID type is string
- Read-only
- Updated upon request
ID | Type | Description |
---|---|---|
sys_uptime | UINT32 | System uptime in seconds. |
sys_serial | String | Device serial number. |
sys_devname | String | Device name. |
sys_devcode | String | Device code. |
sys_version | String | Firmware version. |
sys_hostname | String | Hostname. |
lan_mac | String | LAN MAC address. |
lan_ip | String | IP address of LAN interface. |
lan_mask | String | Subnet mask of LAN interface. |
lan_gateway | String | Gateway IP address of LAN interface. |
lan_dns | Array of String | IP addresses of LAN interface DNS servers. |
rut_wan_ip | String | IP address if WAN is connected. |
rut_wan_type | String | Values of WAN type. |