Product change notifications (PCN) is a way of informing customers of upcoming changes related to Teltonika Networks products. This includes outward appearance adjustments, hardware improvements, changes to package contents, etc. Changes related to a product's firmware are not included in PCNs (click here to see the firmware changelog).
This page stores information regarding changes to the RUT901 device. Below you will find a list of both upcoming and already implemented changes sorted by newest to oldest (top to bottom).
With the release of RutOS version 7.07, RUT901 device will experience changes related to the security improvements of the device.
PCN Number: PCN_RUTOS_CHANGE_2024_03_08_EN
Change description
Change type
Firmware change
Detailed description
Previously, during device resets, logs, RMS connection state data, and SIM PIN settings remained unchanged. However, starting with RutOS firmware version 7.07, all devices will uniformly reset logs, RMS connection state data, and SIM PIN settings to factory defaults when using the reset button. Other reset methods, including WebUI, SMS, and others, will remain unimpacted by this change.
Change reasons
Increasing security
Affected products information
Model
Affected order codes
Order code changes
RUT901
RUT901 ******
No changes
Upcoming change date
2024 Q2, with the release of RutOS 7.07
Change impact
Risk assessment
The loss of device logs upon utilizing the reset button may disrupt operational records and slow down subsequent troubleshooting efforts.
Failure to set up the SIM PIN post-reset via the reset button may result in SIM card lockout due to repeated incorrect PIN entries, causing service disruption and requiring either SIM replacement or PIN reset.
The device is still visible in RMS post-reset but cannot be accessed. Therefore, re-adding the device to RMS is necessary for continued access.
Suggested implementation plan
Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
To download the pdf version of this notification, click here.
Starting from Q2 2024, RUT901 routers will be manufactured with updated MAIN and RF PCB revisions.
Change description
Change type
Hardware change
Detailed description
Starting from Q2 2024, RUT901 routers will be manufactured with updated MAIN and RF PCB revisions. The following are the detailed updates made to the MAIN and RF boards:
Added new USB HUB
Added new USB-UART ICs
Added new ADC
Added SIM card presence triggers to SoC GPIO
Added shift register clearing circuitry
Added pull-down resistors on pins to address potential issues that may arise when shift registers are in the tri-state high-z state.
Please note that this change will be implemented gradually, throughout a 3-month transitional period starting from Q2, 2024. During this period, your shipments of RUT901 may consist of either the current packaging or the new one described above.
Change reasons
Hardware design improvements
Affected products information
Model
Affected order codes
Order code changes
RUT901
RUT901 *****
No changes
Upcoming change date
Q2 2024
Change impact
Risk assessment
New hardware support starts from RUT9M_R_00.07.06 FW version, older FW versions will not be compatible. Custom firmwares created from an SDK will need adjustments for a new SDK version.
Suggested implementation plan
Firmware downloads for the device can be found here.
For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
To download the pdf version of this notification, click here.
2023.09.04: Packaging box changes
Starting from Q4 2023, batch 010, the product packaging of RUT901 will be updated with the following changes.
Change description
Change type
Packaging
Detailed description
The fibre inserts of each product and its accessories will be replaced with individual cardboard boxes. Of those boxes, the product box will include the Teltonika Networks logo and company information, and accessory boxes will include the accessory name, order code, image, EAN barcode, and QR code. Any empty space in the packaging will be filled with Corrugated fibreboard fillers.These updates are meant to reduce the environmental footprint of our products, with eliminating plastic packaging being the primary focus.
Please note that this change will be implemented gradually, throughout a 4-month transitional period starting from Q4 2023, batch 010. During this period, your shipments of RUT901 may consist of either the current packaging or the new one described above. For inquiries regarding custom order codes, please contact your designated sales representative.
Current packaging:
Updated packaging:
Device box:
Corrugated carton filler:
Packaging dimensions will not change.
Change reasons
Design improvement.
Affected products information
Model
Affected order codes
Order code changes
RUT901
RUT901 *****
No changes
Upcoming change date
2023 Q4
Change impact
Risk assessment
The product handling and storage process may require review. Marketing materials, such as photos, might need replacement.
Suggested implementation plan
Information included in this PCN will help adapt to the upcoming changes. For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2023.04.17: Product packaging changes
Starting from 2023 Q2 RUT901 router product packaging will be changed.
Change description
Change type
Packaging
Detailed description
The packaging for the product will undergo several updates including an update to the side print of the box. Additionally, the box will now feature press with certificates that will be printed according to the region. Finally, there will also be changes made to the company information section including the address, telephone number, email and website link.
Current design:
Updated packaging design:
Packaging dimensions will not change.
Change reasons
Design improvement.
Affected products information
Model
Affected order codes
Order code changes
RUT901
RUT901 *****
No changes
Upcoming change date
2023 Q2
Change impact
Risk assessment
The product handling and storage process may require review. Marketing materials, such as photos, might need replacement.
Suggested implementation plan
Information included in this PCN will help adapt to the upcoming changes. For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
To download the pdf version of this notification, click here.
2023.02.13: MAC address range change
All Teltonika Networks devices manufactured starting from 2023, week 9 will have additional new MAC address range.
Change description
Change type
MAC address range
Detailed description
All Teltonika Networks devices manufactured starting from 2023, week 9 may have a MAC address from the new MAC address range 20:97:27:00:00:00 - 20:97:27:FF:FF:FF, as well as the current MAC address range 00:1E:42:00:00:00 - 00:1E:42:FF:FF:FF
Change reasons
Endpoint of the previous MAC address range.
Affected products information
Model
Affected order codes
Order code changes
All Teltonika Networks devices
All order codes
No changes
Upcoming change date
2023, week 9
Change impact
Risk assessment
Device install procedures or any automated solutions might need modifications.
Suggested implementation plan
For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.
To download the pdf version of this notification, click here.