TRM500 Power Consumption

From Teltonika Networks Wiki
Revision as of 07:16, 24 July 2024 by Vainius.l (talk | contribs) (Created page with "TRM power consumption values in different states of operation are represented in the table(s) below:<br> <table class="nd-othertables_3"> <tr style="font-weight:bold">...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > TRM Modems > TRM500 > TRM500 Manual > TRM500 Power Consumption

TRM power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle, no SIM, not connected to other devices (9 V)
14
0.13
Idle, no SIM, not connected to other devices (12 V)
13
0.16
Idle, no SIM, not connected to other devices (24 V)
16
0.38


Test type
Current (mA)
Power consumption (W)
Idle, with SIM inserted, not connected to other devices (9 V)
34
0.31
Idle, with SIM inserted, not connected to other devices (12 V)
31
0.37
Idle, with SIM inserted, not connected to other devices (24 V)
26
0.62


Test type
Current (mA)
Power consumption (W)
Max load* (9 V)
300
2.7
Max load* (12 V)
235
2.82
Max load* (24 V)
131
3.14


* - Max speed 5G (Telia SIM card) transmission.