TSW040 Power Consumption

From Teltonika Networks Wiki
Revision as of 09:50, 16 August 2024 by Tomas (talk | contribs)

Main Page > TSW Switches > TSW040 > TSW040 Manual > TSW040 Power Consumption

Averaged TSW040 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
27
0.24
Idle (12 V)
22
0.26
Idle (24 V)
13
0.31
Idle (44 V)
18
0.79
Idle (54 V)
17
0.92
Idle (57 V)
17
0.97


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
50
0.45
2 LAN devices connected + heavy data traffic1 (12 V)
39
0.47
2 LAN devices connected + heavy data traffic1 (24 V)
22
0.53
2 LAN devices connected + heavy data traffic1 (44 V)
23
1.01
2 LAN devices connected + heavy data traffic1 (54 V)
21
1.13
2 LAN devices connected + heavy data traffic1 (57 V)
21
1.2


Test type
Current (mA)
Power consumption (W)
8 LAN devices connected + heavy data traffic1 (9 V)
113
1.02
8 LAN devices connected + heavy data traffic1 (12 V)
87
1.04
8 LAN devices connected + heavy data traffic1 (24 V)
47
1.13
8 LAN devices connected + heavy data traffic1 (44 V)
38
1.67
8 LAN devices connected + heavy data traffic1 (54 V)
33
1.78
8 LAN devices connected + heavy data traffic1 (57 V)
33
1.88
Test type
Current (mA)
Power consumption (W)
Max load2 (54 V)
2485
134.19


1 - Data streams between devices were created using iPerf.
2 - 4 PoE devices 2 (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic, 4 PoE dummy loads connected (30 W each).
Power consumption may differ due to connected devices, testing environment and conditions.