Test type
Current (mA)
Power consumption (W)
Idle (9 V)
340
3.06
Idle (12 V)
267
3.20
Idle (24 V)
138
3.31


Test type
Current (mA)
Power consumption (W)
1 LAN device connected 1 (9 V)
368
3.31
1 LAN device connected 1 (12 V)
280
3.36
1 LAN device connected 1 (24 V)
155
3.72


Test type
Current (mA)
Power consumption (W)
4 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (9 V)
847
7.63
4 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (12 V)
626
7.51
4 LAN devices connected 1 + high CPU load 2 + USB device connected 3 (24 V)
316
7.58


1 - Data streams between RUTM10 and other connected LAN devices created using iPerf.
2 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
3 - USB device with ~ 300 mA current draw.