TSW110 Powering Options

Revision as of 07:44, 8 October 2020 by Dziugas (talk | contribs) (Created page with "{{Template: networking_tsw1xx_manual_powering_options | name = TSW110 | series = TSW1xx }}")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > TSW Switches > TSW110 > TSW110 Manual > TSW110 Powering Options

This chapter contains information on powering options supported by TSW110 switch.

The switch has a pin power socket and can be powered by a VDC power supply unit (PSU). Refer to the image below for the power socket's pinout information:

Power socket

Ground loops

Do not connect the power supply negative terminal of our device to the chassis or earth exclusively.

This connection could cause ground loops. For example, if the antenna shield and power supply negative terminal are connected to the chassis or earth, it forms a ground loop, therefore unwanted current could flow through a device PCB ground and may cause damage.

In networking switches connecting our device power supply negative terminal to the chassis or earth could cause damage to other devices connected to the switch or unintentional power up of other devices.

Networking rutos manual device recovery option ground loops v1.png