Changes

Created page with "==2022-05-24: RS232 serial interface IC and RS485 TX line change== All RUT955 devices manufactured starting from Q3 2022, will require firmware version '''RUT9_R_00.07.02'''..."
==2022-05-24: RS232 serial interface IC and RS485 TX line change==

All RUT955 devices manufactured starting from Q3 2022, will require firmware version '''RUT9_R_00.07.02''' or newer for the RS232 and RS485 interfaces to function properly.

{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| colspan="2" style="text-align: left; background: white;" |RS232 serial interface IC and RS485 TX line control logic were changed.
|-
| rowspan="3" style="width: 221px; text-align: left; background: white;" |Detailed description
| colspan="2" style="width: 908px; text-align: left; background: white;" |All RUT955 devices manufactured starting from Q3 2022, will require firmware version '''RUT9_R_00.07.02''' or newer for the RS232 and RS485 interfaces to function properly.<br>
RS232 and RS485 functionality will not be supported with previous firmware versions.

Custom Firmware built on previous SDK versions you will also need RUT9_R_00.07.02 or a newer Firmware version to support RS232/RS485 functionality properly.
|-
| style="text-align: left; background: white;" |Change reasons
| colspan="2" style="text-align: left; background: white;" |Reducing product lead times.
|-
|}

{| class="wikitable"
|+
! colspan="2" style="width: 1154px; text-align: left; background: white;" |Affected products information
|-
| colspan="2" style="text-align: left; background: white;" |All RUT955 ****** product codes are affected. No product code changes.
|-

| style="text-align: left; background: white;" |Product release date
| style="text-align: left; background: white;" |Q3 2022
|-
|}

{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change impact
|-
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| colspan="2" style="width: 908px; text-align: left; background: white;" |It is advised to test '''RUT9_R_00.07.02''' Firmware release.
'''Please note:''' this product change notification does not affect any previous RUT955 devices, except new RUT955 devices.
|-
| style="text-align: left; background: white;" |Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |
Firmware downloads for the device can be found [https://wiki.teltonika-networks.com/view/RUT955_Firmware_Downloads here].

For more detailed information please contact your sales representative.
|-
|}

{| class="wikitable"
|+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
|-
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
|-
|}

To download the pdf version of this notification, [[Media:PCN RUT955 2022-05-24 EN.pdf|click here]].