Changes

no edit summary
Line 1: Line 1: −
==2024.05.18: Hardware changes==
+
==2024.05.15: Hardware changes==
   −
Starting from Q3 2024, all {{{name}}} devices will be manufactured with modifications to the RS485 RE/DE management hardware and a new SMA connector.  
+
Starting from Q3 2024, all {{{name}}} devices will be manufactured with modifications to the RS485 RE/DE management hardware.
    
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
| style="width: 1219px; text-align: left; background: #eeece1;" |PCN Number: PCN_RS485_{{{name}}}_2024_05_18_EN
+
| style="width: 1219px; text-align: left; background: #eeece1;" |PCN Number: PCN_RS485_{{{name}}}_2024_05_15_EN
 
|-
 
|-
 
|}
 
|}
Line 11: Line 11:  
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
! colspan="3" style="text-align: left; background: #eeece1;" |Change description
+
! colspan="2" style="text-align: left; background: #eeece1;" |Change description
 
|-
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| style="text-align: left; background: white;" |Change type
| style="text-align: left; background: white;" colspan="2" |Hardware change
+
| style="text-align: left; background: white;" |Hardware change
 
|-
 
|-
| style="width: 221px; text-align: left; background: white;" rowspan="3" | Detailed description
+
| style="width: 221px; text-align: left; background: white;" | Detailed description
| style="width: 908px; text-align: left; background: white;" colspan="2" | In the latest hardware revision of the {{{name}}} device, changes have been made to enhance the management of RS485 signalling. {{{name}}} will require firmware version TRB1_R_00.07.06 or newer to ensure compatibility with the hardware changes and to maintain full functionality. '''Important Note:''' Due to hardware changes, downgrading to firmware versions below, RutOS TRB1_R_00.07.06 is no longer supported.<br>
+
| style="width: 908px; text-align: left; background: white;" | In the latest hardware revision of the {{{name}}} device, changes have been made to enhance the management of RS485 signalling. {{{name}}} will require firmware version TRB1_R_00.07.06 or newer to ensure compatibility with the hardware changes and to maintain full functionality.  
From:
+
'''Important Note:''' Due to hardware changes, downgrading to firmware versions below, RutOS TRB1_R_00.07.06 is no longer supported.<br>
 
  −
RP-SMA Lead-free Female PCB Socket SMD Straight Horizontal Edge Mount 50ohm 0-6GHz VSWR<1.35
  −
 
  −
SMA Female Lead-free PCB Socket SMD Straight Horizontal Edge Mount 50ohm 0-6GHz VSWR<1.35
  −
 
  −
To:
  −
 
  −
RP-SMA Lead-free Female PCB Socket SMD Straight Horizontal Edge Mount 50ohm 
  −
 
  −
SMA Lead-free Female PCB Socket SMD Straight Horizontal Edge Mount 50ohm
  −
 
  −
Please note that this change will be implemented gradually, throughout a 3-month transitional period starting in August 2024. During this period, your shipments of TRB141 may consist of either the current design or the new one described above.
  −
|-
  −
| style="text-align: left; background: white;" | Current design: <br><br> [[File:PCN_RUT260_SMA_Old.PNG|left|400px|link=Special:FilePath/PCN_RUT260_SMA_Old.PNG]]
  −
| style="text-align: left; background: white;" | Updated design: <br><br> [[File:PCN_RUT260_SMA_New.PNG|left|400px|link=Special:FilePath/PCN_RUT260_SMA_New.PNG]]
   
|-
 
|-
 
| style="text-align: left; background: white;" | Change reasons
 
| style="text-align: left; background: white;" | Change reasons
Line 65: Line 50:  
* Devices with the new hardware changes will not support firmware versions below TRB1_R_00.07.06.  
 
* Devices with the new hardware changes will not support firmware versions below TRB1_R_00.07.06.  
 
* Custom firmware built on previous SDK versions will also not be supported.
 
* Custom firmware built on previous SDK versions will also not be supported.
'''Please note''': this product change notification does not affect any previous {{{name}}} devices, except new {{{name}}} devices that will be manufactured with this change.
+
'''Please note''': this product change notification does not affect any previous {{{name}}} devices, except new {{{name}}} devices.
    
|-
 
|-
Line 82: Line 67:  
|}
 
|}
   −
To download the pdf version of this notification, [[Media:{{{name}}}Missing.pdf|click here]].
+
To download the pdf version of this notification, [[Media:PCN_RS485_{{{name}}}_2024_05_15_EN.pdf|click here]].