Line 30: |
Line 30: |
| do | | do |
| date > /tmp/regfile #where data will be stored | | date > /tmp/regfile #where data will be stored |
| + | {{#switch:{{{series}}} |
| + | |RUT9XX = |
| gsmctl -X >> /tmp/regfile | | gsmctl -X >> /tmp/regfile |
| gsmctl -E >> /tmp/regfile | | gsmctl -E >> /tmp/regfile |
| + | |RUT2XX = |
| + | gsmctl -X >> /tmp/regfile |
| + | gsmctl -E >> /tmp/regfile |
| + | |RUTX = |
| + | gsmctl -q >> /tmp/regfile |
| + | gsmctl -c >> /tmp/regfile |
| + | |TRB1 = |
| + | gsmctl -q >> /tmp/regfile |
| + | gsmctl -c >> /tmp/regfile |
| + | |TRB2 = |
| + | gsmctl -q >> /tmp/regfile |
| + | gsmctl -c >> /tmp/regfile |
| + | }} |
| sleep 5 | | sleep 5 |
| done | | done |
Line 71: |
Line 86: |
| | | |
| With Modbus TCP master you can read data just by using ASCII data type and interactive test button. | | With Modbus TCP master you can read data just by using ASCII data type and interactive test button. |
| + | {{#switch:{{{series}}} |
| + | |RUT9XX = [[File:Configuration examples modbus tcp master test.png|border|class=tlt-border]] |
| + | |RUT2XX = [[File:Configuration examples modbus tcp master test.png|border|class=tlt-border]] |
| + | |RUTX = [[File:Configuration examples rutx modbus tcp master test.png|border|class=tlt-border]] |
| + | |TRB1 = [[File:Configuration examples trb1 modbus tcp master test.png|border|class=tlt-border]] |
| + | |TRB2 = [[File:Configuration examples rutx modbus tcp master test.png|border|class=tlt-border]] |
| + | }} |
| | | |
− | [[File:Configuration examples modbus tcp master test.png|border|class=tlt-border]]
| |
| | | |
| To determine how many registers to specify in the '''Register count/Values''' field you should divide character count by two. For example, if you have 28 characters you should input 14 to '''Register count/Values''' field. | | To determine how many registers to specify in the '''Register count/Values''' field you should divide character count by two. For example, if you have 28 characters you should input 14 to '''Register count/Values''' field. |
Line 81: |
Line 102: |
| <ul> | | <ul> |
| <li>Protocol: Modbus TCP;</li> | | <li>Protocol: Modbus TCP;</li> |
− | <li>IP Address: 192.168.3.1 (routers LAN or WAN IP);</li> | + | <li>IP Address: 192.168.{{#ifeq:{{{series}}}|TRB1|2|1}}.1 (routers LAN or WAN IP);</li> |
| <li>Port: 502 (port number on which Modbus TCP Slave is listening);</li> | | <li>Port: 502 (port number on which Modbus TCP Slave is listening);</li> |
| <li>Device: 1</li> | | <li>Device: 1</li> |