<li><b>NC<sub>1</sub></b>, <b>C<sub>1</sub></b> & <b>NO<sub>1</sub></b> - Normally Closed, Common and Normally Open contacts of the internal Non-Latching Relay respectively.<br>Maximum relay ratings: 0.5 A at 60 VDC/70 VAC, 1 A at 30 VDC/VAC.</li> | <li><b>NC<sub>1</sub></b>, <b>C<sub>1</sub></b> & <b>NO<sub>1</sub></b> - Normally Closed, Common and Normally Open contacts of the internal Non-Latching Relay respectively.<br>Maximum relay ratings: 0.5 A at 60 VDC/70 VAC, 1 A at 30 VDC/VAC.</li> | ||
<li><b>NC<sub>2</sub></b>, <b>C<sub>2</sub></b> & <b>NO<sub>2</sub></b> - Normally Closed, Common and Normally Open contacts of the internal Latching Relay respectively.<br>Maximum relay ratings: 0.8 A at 70 VDC, 0.9 A at 70 VAC, 2 A at 30 VDC/VAC.</li> | <li><b>NC<sub>2</sub></b>, <b>C<sub>2</sub></b> & <b>NO<sub>2</sub></b> - Normally Closed, Common and Normally Open contacts of the internal Latching Relay respectively.<br>Maximum relay ratings: 0.8 A at 70 VDC, 0.9 A at 70 VAC, 2 A at 30 VDC/VAC.</li> | ||
<li><b>A</b> - ADC input. Analog voltage range: 0-30 V. The input can be configured for 4-20 mA sensor protocol as current measurement of 0-30 mA.</li> | <li><b>A</b> - ADC input. Analog voltage range: 0-30 V. The input can be configured for 4-20 mA sensor protocol as current measurement (ACL) of 0-30 mA.</li> | ||
<li><b>l</b> and <b>⏚</b> - isolated input contacts. | <li><b>l</b> and <b>⏚</b> - isolated input contacts. | ||
<ul> | <ul> |