Revision as of 14:07, 26 February 2024 by Vainius.l (talk | contribs) (Created page with "<pre> ioman.gpio.dio0 - Configurable input/output (PIN3) ioman.gpio.dio1 - Configurable input/output (PIN4) </pre> Call command <b>ubus call <i>value</i> status</b>: root@T...")
ioman.gpio.dio0 - Configurable input/output (PIN3) ioman.gpio.dio1 - Configurable input/output (PIN4)
Call command ubus call value status:
root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio0 status { "value": "0", "direction": "in", "bi_dir": false, "invert_input": false }
- dio0 is configurable input / output:
- "value": "0" means low level state.
- "value": "1" means high level state.
- "direction": "in" means input state.
- "direction": "out" means output state.
To change input settings, use the update command and specify a value:
ubus call ioman.gpio.dio0 update '{"value":"0"}' ubus call ioman.gpio.dio0 update '{"value":"1"}' ubus call ioman.gpio.dio0 update '{"direction":"in"}' ubus call ioman.gpio.dio0 update '{"direction":"out"}'