TSF010 Power Consumption

From Teltonika Networks Wiki
Revision as of 10:35, 8 April 2024 by Vainius.l (talk | contribs) (Created page with "TSF010 power consumption values in different states of operation are represented in the table(s) below:<br> <table class="nd-othertables_3"> <tr style="font-weight:bold">...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > TSF Switches > TSF010 > TSF010 Manual > TSF010 Power Consumption

TSF010 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
26
0.24
Idle (12 V)
21
0.25
Idle (24 V)
12
0.30


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
99
0.86
2 LAN devices connected + heavy data traffic1 (12 V)
74
0.89
2 LAN devices connected + heavy data traffic1 (24 V)
43
1.03


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
204
1.84
5 LAN devices connected + heavy data traffic1 (12 V)
154
1.85
5 LAN devices connected + heavy data traffic1 (24 V)
86
2.07


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.