TSW040 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
27
0.24
Idle (12 V)
22
0.26
Idle (24 V)
13
0.31
Idle (44 V)
18
0.79
Idle (54 V)
17
0.92
Idle (57 V)
17
0.97


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
50
0.45
2 LAN devices connected + heavy data traffic1 (12 V)
39
0.47
2 LAN devices connected + heavy data traffic1 (24 V)
22
0.53
2 LAN devices connected + heavy data traffic1 (44 V)
23
1.01
2 LAN devices connected + heavy data traffic1 (54 V)
21
1.13
2 LAN devices connected + heavy data traffic1 (57 V)
21
1.2


Test type
Current (mA)
Power consumption (W)
8 LAN devices connected + heavy data traffic1 (9 V)
113
1.02
8 LAN devices connected + heavy data traffic1 (12 V)
87
1.04
8 LAN devices connected + heavy data traffic1 (24 V)
47
1.13
8 LAN devices connected + heavy data traffic1 (44 V)
38
1.67
8 LAN devices connected + heavy data traffic1 (54 V)
33
1.78
8 LAN devices connected + heavy data traffic1 (57 V)
33
1.88
Test type
Current (mA)
Power consumption (W)
Max load2 (54 V)
2485
134.19


1 - Data streams between devices were created using iPerf.
2 - 4 PoE devices 2 (RUTX08, RUTX09, RUTX10, RUTX11) connected + heavy data traffic, 4 PoE dummy loads connected (30 W each).