Template:Networking trb16 manual input output status

From Teltonika Networks Wiki
Revision as of 10:08, 25 June 2024 by Vainius.l (talk | contribs) (Created page with "<pre> ioman.gpio.dio0 ioman.gpio.dio1 </pre> In order to read values, call command <b>ubus call <i>value</i> status </b>: root@Teltonika-{{{name}}}:~# ubus call ioman.gpio....")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
ioman.gpio.dio0
ioman.gpio.dio1

In order to read values, call command ubus call value status :

root@Teltonika-{{{name}}}:~# ubus call ioman.gpio.dio1 status
{
        "value": "0",
        "direction": "in",
        "bi_dir": false,
        "invert_input": false
}
  • dio0 is configurable input / output:
    • "value": "0" means low level state.
    • "value": "1" means high level state.
    • "direction": "in" means input state.
    • "direction": "out" means output state.

To change input settings, use the update command and specify a value:

ubus call ioman.gpio.dio0 update '{"value":"0"}'
ubus call ioman.gpio.dio0 update '{"value":"1"}'
ubus call ioman.gpio.dio0 update '{"direction":"in"}'
ubus call ioman.gpio.dio0 update '{"direction":"out"}'