Template:Networking device manual powering options ground loops switches

Revision as of 10:18, 27 June 2024 by Vainius.l (talk | contribs) (Created page with "==Ground loops== Do not connect the power supply negative terminal of our device to the chassis or earth exclusively. This connection could cause ground loops. For example,...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

Ground loops

Do not connect the power supply negative terminal of our device to the chassis or earth exclusively.

This connection could cause ground loops. For example, if the antenna shield and power supply negative terminal are connected to the chassis or earth, it forms a ground loop, therefore unwanted current could flow through a device PCB ground and may cause damage.

In networking switches connecting our device power supply negative terminal to the chassis or earth could cause damage to other devices connected to the switch or unintentional power up of other devices.

Networking rutos manual device recovery option ground loops v1.png