RUTC50 Power Consumption

From Teltonika Networks Wiki
Revision as of 10:09, 16 August 2024 by Tomas (talk | contribs)

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > RUTC Routers > RUTC50 > RUTC50 Manual > RUTC50 Power Consumption

Averaged RUTC50 power consumption values in different states of operation are represented in the tables below:

Test type
Current (mA)
Power consumption (W)
Idle, no SIM card inserted (9 V)
539
4.85
Idle, no SIM card inserted (12 V)
400
4.80
Idle, no SIM card inserted (24 V)
201
4.84


Test type
Current (mA)
Power consumption (W)
Idle + mobile data on 1 (9 V)
551
4.96
Idle + mobile data on 1 (12 V)
408
4.89
Idle + mobile data on 1 (24 V)
204
4.92


Test type
Current (mA)
Power consumption (W)
Mobile data on 1 + 1 LAN device connected 2 (9 V)
610
5.49
Mobile data on 1 + 1 LAN device connected 2 (12 V)
449
5.39
Mobile data on 1 + 1 LAN device connected 2 (24 V)
227
5.45


Test type
Current (mA)
Power consumption (W)
Max speed 5G (NSA) transmission + 5 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi + GPS on +
USB device connected 4 (9 V)
1478
13.3
Max speed 5G (NSA) transmission + 5 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi + GPS on +
USB device connected 4 (12 V)
1041
12.49
Max speed 5G (NSA) transmission + 5 LAN devices connected 2 + high CPU load 3 + data transfer via WiFi + GPS on +
USB device connected 4 (24 V)
504
12.10

1 - Only mobile data connection established with no additional traffic.
2 - Data streams between RUTC50 and other connected LAN devices created using iPerf.
3 - Load created using md5sum (calculation and verification of 128-bit MD5 hashes).
4 - USB device with ~ 500 mA current draw.
Power consumption may differ due to mobile data transmission speed, testing environment and conditions.