TSF010 UKCA

From Teltonika Networks Wiki
Revision as of 12:25, 29 October 2024 by Robertas. Jonkus (talk | contribs) (Created page with "thumb|right|150px|UKCA logo The <b> UK Conformity Assessment (UKCA) </b> is the UK product marking requirement that is required for products placed on...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > TSF Switches > TSF010 > TSF010 Certification & Approvals > TSF010 UKCA
UKCA logo

The UK Conformity Assessment (UKCA) is the UK product marking requirement that is required for products placed on the market in Great Britain (England, Scotland and Wales), substituting the EU requirements for CE Marking (CE marking will continue to be accepted in Northern Ireland). UKCA marking indicates that a product placed on the United Kingdom market meets the UKCA Marking requirements.

To view UK PSTI declaration click click here.

Description

UK started to use its own regulations instead of EU directives. Three of these regulations are shown on this table with its EU equivalences:

UK Regulation European Directive
EMC Regulations 2016 (S.I. 2016/1091) EMC Directive (2014/30/EU)
Radio Equipments Regulations 2017 (S.I. 2017/1206) Radio Equipment Directive (RED) (2014/53/EU)
Electrical Equipment (Safety) Regulations 2016 (S.I. 2016/1101) Low Voltage Directive (LVD) (2014/35/EU)

Even though names of UK regulations differs from European directives, they are using similar or same standards. UKCA marking uses its own designated standards and CE marking uses its harmonised standards to fulfil requirements of the listed regulation/directive. Also, UK is still using standards that are also acceptable for CE compliance.

The UKCA marking can be used from 1st January 2021.

Standards applied

The conformity with the essential requirements has been demonstrated against the following designated standards:

Standard Regulation
EN IEC 62368-1:2018 Electrical Equipment (Safety) Regulations 2016 (S.I. 2016/1101)
EN 55032:2015 + A1:2020+A11:2020
EN 61000-3-3:2013 + A1:2019 + A2:2021
EN IEC 61000-3-2:2019 + A1:2021
EN 55035:2017+A11:2020
EMC Regulations 2016 (S.I. 2016/1091)

Therefore is placed on the product.