Averaged TRB141 power consumption values in different states of operation are represented in the tables below:

Test type
Current (mA)
Power consumption (W)
Idle, no SIM card inserted (9 V)
80
0.72
Idle, no SIM card inserted (12 V)
61
0.73
Idle, no SIM card inserted (24 V)
35
0.84


Test type
Current (mA)
Power consumption (W)
Idle + mobile data on 1 (9 V)
105
0.94
Idle + mobile data on 1 (12 V)
78
0.94
Idle + mobile data on 1 (24 V)
43
1.03


Test type
Current (mA)
Power consumption (W)
Mobile data on 1 + 1 LAN device connected 2 (9 V)
114
1.03
Mobile data on 1 + 1 LAN device connected 2 (12 V)
89
1.07
Mobile data on 1 + 1 LAN device connected 2 (24 V)
56
1.34


Test type
Current (mA)
Power consumption (W)
Max speed LTE transmission + 1 LAN devices connected 2 + high CPU load 3 + all outputs enabled on I/O panel (9 V)
740
6.66
Max speed LTE transmission + 1 LAN devices connected 2 + high CPU load 3 + all outputs enabled on I/O panel (12 V)
545
6.54
Max speed LTE transmission + 1 LAN devices connected 2 + high CPU load 3 + all outputs enabled on I/O panel (24 V)
290
6.96