Product change notifications (PCN) is a way of informing customers of upcoming changes related to Teltonika Networks products. This includes outward appearance adjustments, hardware improvements, changes to package contents, etc. Changes related to a product's firmware are not included in PCNs (click here to see the firmware changelog).

This page stores information regarding changes to the RUT951 device. Below you will find a list of both upcoming and already implemented changes sorted by newest to oldest (top to bottom).

2025.08.21: eSIM Bootstrap capability

Starting from 2026 Q1, RUT951 eSIM will include a bootstrap profile, which enables the download of an initial operational eSIM profile without requiring an additional internet connection.

Change Notification!

  • As of 2025-11-24 an additional revision has been made to this PCN document: previous change date of 2025 Q4 was revised an is now 2026 Q1
  • As of 2025-09-03, a revision has been made to this PCN document: clarification added that Bootstrap functionality is officially supported from firmware version RUT9M_R_00.07.17.2 or newer.
PCN Number: PCN_RUT951_esim_bootstrap_2025.08.21
Change description
Change type eSIM service enhancement
Detailed description

• Addition of bootstrap profile to eSIM
• Automated SIM switching functionality when no physical SIM is present and bootstrap profile is active
• Device with active bootstrap profile will have access only to RMS (Remote Management System) with limited functionality and SM-DP server for downloading operational profile
• Bootstrap profile has a 10 MB mobile data limit
• Bootstrap profile is valid for 1 year, starting from the manufacturing date of the device

Read the following eSIM Bootstrap guide to familiarize yourself with the functionality.

Bootstrap functionality is officially supported from firmware version RUT9M_R_00.07.17.2 or newer.

Change reasons Simplified eSIM activation process and improved provisioning automation
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 03****, 13**** No changes
Upcoming change date 2026 Q1
Change impact
Risk assessment

• Device initial provisioning workflows may require review or adjustment to account for the presence of a bootstrap profile
• Installation procedures or automated deployment tools may need to be updated if they rely on predefined SIM behavior
• Automatic SIM switching will be enabled only on devices shipped with a pre-installed bootstrap profile — existing devices with eSIM but no bootstrap profile will not exhibit any behavioral changes
• Devices manufactured over 12 months prior to activation may be unable to use the bootstrap profile due to expiration

Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. Learn more eSIM Bootstrap. For more detailed information, please contact your sales representative.

Supported country list

EMEA APAC AMERICAS Territories / Special Regions
Albania Austria Belgium Bulgaria China Brazil Gibraltar
Croatia Cyprus Czech Republic Denmark Hong Kong Canada Guadeloupe
Estonia Finland France Georgia India Colombia Northern Mariana Islands
Germany Greece Hungary Iceland Indonesia Costa Rica Réunion
Ireland Italy Latvia Liechtenstein Malaysia Mexico
Lithuania Luxembourg Malta Montenegro Singapore United States of America
Netherlands Norway Poland Portugal Sri Lanka
Romania Slovakia Slovenia South Africa Taiwan
Spain Sweden Switzerland United Kingdom Vietnam
Egypt Saudi Arabia Kuwait Qatar Australia
Turkey Tunisia
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the PDF version of this notification, click here.

2025.07.22: New RUT951 hardware revision

Starting from Q3 2025, RUT951 routers will be manufactured with updated hardware and will require firmware version RUT9M_R_00.07.10 or newer to function properly.


PCN Number: PCN_RUT951_New_HW_revision_2025_07_22
Change description
Change type Hardware change
Detailed description

All RUT951 devices manufactured starting from Q3 2025 will feature a new hardware revision. Devices with the new hardware will require firmware version RUT9M_R_00.07.10 or newer. It is recommended to use the latest firmware version, at least RUT9M_R_00.07.15.

Starting from Q3 2025, RUT951 devices will include the following hardware changes:

  • Added possibility to manufacture with eSIM

Please note that this change will be implemented gradually, throughout a 3-month transitional period starting from Q3 2025. During this period, your shipments of RUT951 may consist of either the current or the new hardware as described above.

Change reasons Hardware design improvements
Affected products information
Model Affected order codes Order code changes
RUT951 All No changes
Upcoming change date Q3 2025
Change impact
Risk assessment

All risks are firmware-related. It is strongly advised to test firmware release RUT9M_R_00.07.10 or newer on the updated RUT951 hardware revision devices.

New hardware support starts from RUT9M_R_00.07.10 FW version, older FW versions will not be compatible. Custom firmwares created from an SDK will need adjustments for a new SDK version.

Suggested implementation plan

Firmware downloads for the device can be found here. For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the PDF version of this notification, click here.

2025.05.28: Transition to HTTPS protocol RutOS 7.15

With the release of RutOS version 7.15 in Q2 2025, RUT951 devices will disable the HTTP protocol and enable HTTPS Redirect by default to enhance WebUI and API communication security.

PCN Number: PCN_Transition_HTTPS_RUT951_2025_05_28
Change description
Change type RutOS Security Enhancement
Detailed description With the release of RutOS version 7.15 firmware, the device's WebUI and API default communication methods will change. The HTTP protocol will be changed to HTTPS (only) in default configuration for security reasons and complying with security standards. The "HTTPS Redirect" functionality will be enabled by default so all HTTP requests will be automatically redirected through the HTTPS channel.
Change reasons To enhance security measures and comply with security standards by eliminating unsecured HTTP protocol usage.
Affected products information
Model Affected order codes Order code changes
RUT951 All No changes
Upcoming change date Q2 2025
Change impact
Risk assessment
  • Users may receive a browser warning indicating that the connection is not secure due to the use of a self-signed certificate in HTTPS.
  • API users may experience issues depending on the tools they use to communicate with the API, as some may not support HTTPS, self-signed certificates or the tooling may have to be reconfigured to adapt to these changes.
Suggested implementation plan
  • Information included in this PCN will help adapt to the upcoming changes. URL1 URL2 For more detailed information, please contact your sales representative.
  • API users should update their tools and scripts to support HTTPS communication and handle self-signed certificates.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the PDF version of this notification, click here.

2025.02.25: Mobile and I/O POST/GET Service Removal with RutOS 7.14

With the release of RutOS version 7.14, support for the RUT951 POST/GET service will be discontinued to enhance security while maintaining device functionality through alternative methods.

PCN Number: PCN_RUTOS 7.14_POST_GET_Removal_RUT951_2025_02_25_EN
Change description
Change type Firmware change
Detailed description With the introduction of RutOS 7.14, the Mobile POST/GET and I/O POST/GET services will be removed from the firmware and will no longer be available in the package manager. These legacy services had security concerns, and their removal ensures a more robust security framework for the device. However, users will still be able to achieve the same functionalities using the device's API, which provides a more secure and efficient way to interact with the system.
Change reasons
  • Enhanced Security: Removing these services mitigates potential security risks and improves overall system integrity.
  • Improved API Support: Users can leverage the API for secure and flexible data handling without relying on deprecated methods.
  • The change aligns with modern security protocols and best practices in remote device management.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ****** No changes
Upcoming change date 2025 Q2, with the release of RutOS 7.14
Change impact
Risk assessment
  • Clients using Mobile POST/GET and I/O POST/GET services will need to transition to API-based methods.
  • Some automation processes relying on these legacy services may require reconfiguration
  • API documentation and support resources will be available to facilitate a smooth transition.
Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2025.02.24: Implementation of Read-Only System Files in RutOS 7.14

With the release of RutOS version 7.14 in Q2 2025, in RUT951 devices will implement read-only permissions for critical system files by default. The new read-only configuration ensures a more secure and stable environment, though it may affect those who perform non-standard operations.

PCN Number: PCN_read_only_system_RUT951_2025_02_24
Change description
Change type RutOS System Integrity Enhancement
Detailed description With the release of RutOS version 7.14, the device’s critical system files will become read-only by default. This prevents unauthorized or accidental modifications that could damage the system’s integrity. Standard users operating within typical parameters should not be affected, while those who rely on direct file alterations will need to adjust their workflows. Custom firmware options are expected to allow reverting to a more flexible configuration if required.
Change reasons To maintain system integrity, enhance reliability, and prevent unintended damage to core files.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ****** No changes
Upcoming change date Q2 2025
Change impact
Risk assessment
  • Customers performing direct system-level modifications may need to adjust their procedures.
  • Standard end-users, who do not rely on altering critical system files, are unlikely to be affected.
  • Custom firmware solutions can restore file-level flexibility if required.
Suggested implementation plan
  • Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.
  • Review current workflows and identify any reliance on direct system file modifications. Consider using custom firmware builds if continued system-level customization is necessary.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification, Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the PDF version of this notification, click here.


2025.02.20: WebUI Mode Update with RutOS 7.13

With the release of RutOS version 7.13, RUT951 the WebUI will undergo changes to enhance user experience and accessibility.

PCN Number: PCN_RUTOS_CHANGE_RUT951_2025_02_20_EN
Change description
Change type Firmware change
Detailed description Previously, the WebUI provided two separate modes: Basic Mode and Advanced Mode. With the introduction of RutOS 7.13, these two modes will be merged into a unified interface, where users will have access to all settings within one mode.
Change reasons
  • Improved Usability: A single mode simplifies navigation and enhances user-friendliness.
  • Increased Accessibility: All essential settings remain available without needing to switch between modes.
  • Optimized User Experience: A streamlined design enhances efficiency and ease of use.
  • User-Driven Enhancement: This change is based on user feedback, aiming to create a more intuitive and accessible WebUI experience.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ****** No changes
Upcoming change date 2025 Q2, with the release of RutOS 7.13
Change impact
Risk assessment
  • Users accustomed to switching between Basic and Advanced Mode may require time to adapt to the unified interface.
  • Settings will now be presented in a single, continuous view rather than separated into different modes.
  • Minor learning curve for users transitioning from previous WebUI versions.
Suggested implementation plan
  • Review the unified WebUI mode and familiarize yourself with having all settings available.
  • Refer to the updated user documentation and support resources for guidance.

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2025.01.22: Accessory mobile SMA replacement

Starting from 2025 Q1, for specific order codes the product accessory mobile SMA antenna in the standard package will be replaced.

PCN Number: PCN_SMA_antenna_Accessory_change_2025_01_22_EN
Change description
Change type Replacement
Detailed description Starting from 2025 Q1, for specific order codes (listed below), the product accessory mobile SMA antenna in the standard package is replaced with a mobile SMA antenna from a different manufacturer.
Specification Comparison
Parameter Previous Current
Frequency range 698 ~ 960, 1710 ~ 2690 MHz 600 ~ 2700 MHz
Polarization Linear (vertical) Linear
Gain 4.0 dBi ≤ 2.9 dBi
VSWR 3.0 ≤ 4.7
Impedance 50 Ω 50 Ω
Connector type SMA Male SMA Male
Operating temperature –40 °C ~ +85 °C -20 °C to +70 °C
RoHS compliant
Weight 20 g 19.5 g
Change reasons Reducing product lead times
Affected products information
Affected Order Codes
  • RUT2410340H0
  • RUT241087000
  • TRB245400800
  • TRB14040C400
  • TRB14140A300
  • TRB14240A700
  • TRB143400300
  • TRB143400400
  • TRB14540A300
  • RUT951900A00
  • RUT956900C00
  • RUT956900D00
Upcoming change date 2025 Q1
Change impact
Risk assessment No risk factors encountered with this change.
Suggested implementation plan No implementation plan needed.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.


2024.12.19: Tamper evident sticker

Beginning in January 2025, RUT951 devices will packaged in a box with a tamper evident sticker.

PCN Number: PCN_RUT951_Tamper evident sticker_2024.12.19_EN
Change description
Change type Packaging changes
Detailed description RUT951 devices will be packaged with tamper evident sticker on the box.


Please note that this change will be implemented gradually, throughout a 3-month transitional period starting in January 2025. During this period, your shipments of RUT951 may consist of either the current packaging or the new one described above.

Seal on:
Seal removed:
Change reasons To enhance security and ensure reliability by confirming packaging integrity.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ****** (For North America region order codes) N/A
Upcoming change date 2025 January
Change impact
Risk assessment
  • The sticker may leave residue on the box, affecting the packaging's appearance.
  • Marketing material such as photos might need replacing.
Suggested implementation plan Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2024.09.18: EAN Code Change

Starting from October 1st 2024, new order codes created will have their own unique EAN codes.

PCN Number: PCN_EAN_Code_Change_RUT951_2024.09.18_EN
Change description
Change type Logistics change
Detailed description The product identification system is being updated by assigning unique EAN codes to each new order code created from October 1st.
Change reasons Improving product traceability, inventory management, and logistics accuracy across ordering and distribution systems.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ***** No changes
Upcoming change date October 1st, 2024
Change impact
Risk assessment

Every order code, created after this change, will have its own unique EAN code. Therefore, it might cause the need to review inventory management and ordering processes.

Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2024.05.15: New PCB revision

Starting from Q3 2024, RUT951 router will be manufactured with updated MAIN and RF PCB revisions.

PCN Number: PCN_RUT951_New_PCB_Revision_2024.05.15
Change description
Change type Hardware change
Detailed description Starting from Q3 2024, RUT951 router will be manufactured with updated MAIN and RF PCB revisions. The following are the detailed updates made to the MAIN and RF boards:
  • Added SIM card presence triggers to SoC GPIO
  • Added shift register clearing circuitry
  • Added pull-down resistors on pins to address potential issues that may arise when shift registers are in the tri-state high-z state.

Please note that this change will be implemented gradually, throughout a 3-month transitional period starting from Q3, 2024. During this period, your shipments of RUT951 may consist of either the current MAIN and RF PCB or the new one described above.

Change reasons Hardware design improvements
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ***** (except order codes RUT951 A****) No changes
Upcoming change date Q3 2024
Change impact
Risk assessment No risk factors have been identified during the evaluation of this change. However, it is recommended to conduct an independent review to ensure alignment with specific circumstances and requirements.
Suggested implementation plan

The information included in this PCN will help adapt to the upcoming changes. For more detailed information, please get in touch with your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2024.03.08: Reset button functionality change RutOS 7.07

With the release of RutOS version 7.07, RUT906 device will experience changes related to the security improvements of the device.

PCN Number: PCN_RUTOS_CHANGE_2024_03_08_EN
Change description
Change type Firmware change
Detailed description Previously, during device resets, logs, RMS connection state data, and SIM PIN settings remained unchanged. However, starting with RutOS firmware version 7.07, all devices will uniformly reset logs, RMS connection state data, and SIM PIN settings to factory defaults when using the reset button. Other reset methods, including WebUI, SMS, and others, will remain unimpacted by this change.
Change reasons Increasing security
Affected products information
Model Affected order codes Order code changes
RUT906 RUT906 ****** No changes
Upcoming change date 2024 Q2, with the release of RutOS 7.07
Change impact
Risk assessment
  • The loss of device logs upon utilizing the reset button may disrupt operational records and slow down subsequent troubleshooting efforts.
  • Failure to set up the SIM PIN post-reset via the reset button may result in SIM card lockout due to repeated incorrect PIN entries, causing service disruption and requiring either SIM replacement or PIN reset.
  • The device is still visible in RMS post-reset but cannot be accessed. Therefore, re-adding the device to RMS is necessary for continued access.
Suggested implementation plan

Information included in this PCN will help adapt to the upcoming changes. For more detailed information, please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2024.01.10: New PCB revision

RUT951 PCN "2024.01.10: New PCB revision" was updated with the information and is replaced with RUT951 PCN "2024.05.15: New PCB revision".

Starting from Q2 2024, RUT951 routers will be manufactured with updated MAIN and RF PCB revisions.

Change description
Change type Hardware change
Detailed description Starting from Q2 2024, RUT951 routers will be manufactured with updated MAIN and RF PCB revisions. The following are the detailed updates made to the MAIN and RF boards:
  • Added new USB HUB
  • Added new USB-UART ICs
  • Added new ADC
  • Added SIM card presence triggers to SoC GPIO
  • Added shift register clearing circuitry
  • Added pull-down resistors on pins to address potential issues that may arise when shift registers are in the tri-state high-z state.

Please note that this change will be implemented gradually, throughout a 3-month transitional period starting from Q2, 2024. During this period, your shipments of RUT951 may consist of either the current packaging or the new one described above.

Change reasons Hardware design improvements
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ***** No changes
Upcoming change date Q2 2024
Change impact
Risk assessment New hardware support starts from RUT9M_R_00.07.06 FW version, older FW versions will not be compatible. Custom firmwares created from an SDK will need adjustments for a new SDK version.
Suggested implementation plan

Firmware downloads for the device can be found here. For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.


2023.09.04: Packaging box changes

Starting from Q4 2023, batch 017, the product packaging of RUT951 will be updated with the following changes.

Change description
Change type Packaging
Detailed description The fibre inserts of each product and its accessories will be replaced with individual cardboard boxes. Of those boxes, the product box will include the Teltonika Networks logo and company information, and accessory boxes will include the accessory name, order code, image, EAN barcode, and QR code. Any empty space in the packaging will be filled with Corrugated fibreboard fillers. These updates are meant to reduce the environmental footprint of our products, with eliminating plastic packaging being the primary focus.

Please note that this change will be implemented gradually, throughout a 4-month transitional period starting from Q4 2023, batch 017. During this period, your shipments of RUT951 may consist of either the current packaging or the new one described above. For inquiries regarding custom order codes, please contact your designated sales representative.

Current packaging:


Updated packaging:


Device box:

Corrugated carton filler:

Packaging dimensions will not change.
Change reasons Design improvement.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ***** No changes
Upcoming change date 2023 Q4
Change impact
Risk assessment The product handling and storage process may require review. Marketing materials, such as photos, might need replacement.
Suggested implementation plan Information included in this PCN will help adapt to the upcoming changes. For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2023.06.07: QSG flyer replacement

Starting in Q3 of 2023, RUT951 routers will come with a new QSG flyer in the packaging.

Change description
Change type Replacement of QSG flyer
Detailed description RUT951 devices manufactured starting from Q3 2023 will have a new QSG flyer in the packaging. The new QSG flyer includes multiple languages, English, German, Spanish, French, Italian, the short version of QSG with a QR code/link to the full Web QSG version: teltonika-networks.com/QSG_RUT951
Previous design:
New design:
The new flyer will include QR codes with URL links to RMS and the Web version of the QSG (Quick Start Guide) for the RUT951.
Change reasons Introducing additional languages.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ****** No changes
Upcoming change date 2023, Q3
Change impact
Risk assessment Marketing material such as photos might need replacing.
Suggested implementation plan Information included in this PCN will help adapt to the upcoming changes.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.


2023.04.17: Product packaging changes

Starting from 2023 Q2 RUT951 router product packaging will be changed.

Change description
Change type Packaging
Detailed description The packaging for the product will undergo several updates including an update to the side print of the box. Additionally, the box will now feature press with certificates that will be printed according to the region. Finally, there will also be changes made to the company information section including the address, telephone number, email and website link.
Current design:

Updated packaging design:

Packaging dimensions will not change.
Change reasons Design improvement.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ***** No changes
Upcoming change date 2023 Q2
Change impact
Risk assessment The product handling and storage process may require review. Marketing materials, such as photos, might need replacement.
Suggested implementation plan Information included in this PCN will help adapt to the upcoming changes. For more detailed information please contact your sales representative.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2023.02.13: MAC address range change

All Teltonika Networks devices manufactured starting from 2023, week 9 will have additional new MAC address range.

Change description
Change type MAC address range
Detailed description All Teltonika Networks devices manufactured starting from 2023, week 9 may have a MAC address from the new MAC address range 20:97:27:00:00:00 - 20:97:27:FF:FF:FF, as well as the current MAC address range 00:1E:42:00:00:00 - 00:1E:42:FF:FF:FF
Change reasons Endpoint of the previous MAC address range.
Affected products information
Model Affected order codes Order code changes
All Teltonika Networks devices All order codes No changes
Upcoming change date 2023, week 9
Change impact
Risk assessment Device install procedures or any automated solutions might need modifications.
Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above.

To download the pdf version of this notification, click here.

2022.08.18: Default password change

All RUT951 devices manufactured starting from 2022, week 35, will have unique default password.

Change description
Change type Default password change
Detailed description RUT951 devices manufactured starting from Q3 2022 will have unique default password.
Change reasons Increasing device security
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ****** No changes
Upcoming change date 2022, week 35
Change impact
Risk assessment Device install procedures or any automated solutions might need modifications. Please note: this product change notification does not affect any previous RUT951 devices.
Suggested implementation plan

For more detailed information please contact your sales representative.

Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2022.08.18: QSG flyer replacement

Starting from 2022, week 35, RUT951 routers will come with a new QSG flyer in the packaging.

Change description
Change type Replacement of QSG flyer
Detailed description RUT951 devices manufactured starting from Q3 2022 will have a new QSG flyer in the packaging. The new QSG flyer includes the short version of QSG with a QR code/link to the full Web QSG version: teltonika-networks.com/QSG_RUT951
Previous design:
New design:
The new flyer will include QR codes with URL links to RMS and the Web version of the QSG (Quick Start Guide) for the RUT951.
Change reasons Reducing environmental impact.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ****** No changes
Upcoming change date 2022, week 35
Change impact
Risk assessment Marketing material such as photos might need replacing.
Suggested implementation plan Information included in this PCN will help adapt to the upcoming changes.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.

2022.08.18: Changes in engraving/labeling

Starting from 2022, week 35, RUT951 routers will be produced with modified bottom engraving/labeling.

Change description
Change type External/visual
Detailed description The device's unique default password will be added to the bottom engraving/labeling. The formatting for the remaining information on the labeling/engraving will be adjusted, and the Fira font will be used instead of Arial. The device's unique default password information will also be added to the QR code Information displayed after scanning QR code with syntax: WIFI:T:WPA;S:{{WIFISSID}};P:{{PASSWORD}};SN:{{SERIAL}};I:{{IMEI}};M:{{MAC}};U:admin;PW:{{DEVICEPASSWORD}};B:{{BATCH}};


From the device top engraving/labeling, the previously relevant authentication information text will be removed: User/Pass: admin/admin01.


The labeling on the product packaging will stay unchanged.

Old top engraving/labeling:

Old bottom engraving/labeling:

New top engraving/labeling:

New bottom engraving/labeling:

Change reasons To accommodate the change from the standard default password to a unique default password for each device.
Affected products information
Model Affected order codes Order code changes
RUT951 RUT951 ****** No changes
Upcoming change date 2022, week 35
Change impact
Risk assessment Changes to top labeling/engraving. Device's unique default password will be present on the product itself. This might impact marketing materials due to changing contents of the bottom informational engraving/labeling.
Suggested implementation plan No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above

To download the pdf version of this notification, click here.