value to set register number register value description
Digital output 1 (DOUT1) (ON/OFF*) 201 1 | 0 Changes the state of the open collector (OC) output
Digital output 2 (DOUT2) (ON/OFF*) 202 1 | 0 Changes the state of the relay output
Switch WiFi (ON/OFF*) 210 1 | 0 Turns WiFi ON or OFF
Switch mobile data connection (ON/OFF*) 211 1 | 0 Turns mobile data connection ON or OFF
Switch SIM card 212 1 | 2 | 0 Changes the active SIM card slot
  • 1 - switch to SIM1
  • 2 - switch to SIM2
  • 0 - switch from the the SIM card opposite of the one currently in use (SIM1 → SIM2 or SIM2 → SIM1
Change APN 213 APN code Changes APN.
The number of input registers may vary depending on the length of the APN, but the very first byte of the set APN command denotes the number of the SIM card for which to set the APN. This byte should be set to:
  • 1 - to set APN for SIM1
  • 2 - to set APN for SIM2
Reboot 220 1 Reboots the router