Template:Networking rut2xx manual modbus modbus tcp get parameters table

From Teltonika Networks Wiki
Revision as of 16:41, 6 December 2018 by Dziugas (talk | contribs)

required value register number number of registers representation
System uptime 1 2 32 bit unsigned integer
Mobile signal strength (RSSI in dBm) 3 2 32 bit integer
System temperature (in 0.1 °C) 5 2 32 bit integer
System hostname 7 16 Text
GSM operator name 23 16 Text
Router serial number 39 16 Text
LAN MAC address 55 16 Text
Router name 71 16 Text
Currently active SIM card slot 87 16 Text
Network registration info 103 16 Text
Network type 119 16 Text
Current WAN IP address 139 16 32 bit unsigned integer


data usage values*
Mobile data received today 135 2 32 bit integer
Mobile data sent today 137 2 32 bit integer
Mobile data received this week 141 2 32 bit integer
Mobile data sent this week 143 2 32 bit integer
Mobile data received this month 145 2 32 bit integer
Mobile data sent this month 147 2 32 bit integer
Mobile data received in the last 24 hours 149 2 32 bit integer
Mobile data sent in the last 24 hours 151 2 32 bit integer
Mobile data received in the last 7 days 153 2 32 bit integer
Mobile data sent in the last 7 days 155 2 32 bit integer
Mobile data received in the last 30 days 157 2 32 bit integer
Mobile data sent in the last 30 days 159 2 32 bit integer