Template:Networking rut900 manual modbus modbus tcp get parameters table

From Teltonika Networks Wiki
Revision as of 12:54, 23 July 2019 by Dziugas (talk | contribs) (Created page with "<table class="nd-othertables"> <tr> <th width="546">required value</th> <th width="200">register number</th> <th width="200">number of registers</t...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
required value register number number of registers representation
System uptime 1 2 32 bit unsigned integer
Mobile signal strength (RSSI in dBm) 3 2 32 bit integer
System temperature (in 0.1 °C) 5 2 32 bit integer
System hostname 7 16 Text
GSM operator name 23 16 Text
Router serial number 39 16 Text
LAN MAC address 55 16 Text
Router name 71 16 Text
Currently active SIM card slot 87 16 Text
Network registration info 103 16 Text
Network type 119 16 Text
Current WAN IP address 139 16 32 bit unsigned integer