required value | register address | register number | number of registers | representation |
---|---|---|---|---|
Hostname | 7 | 8 | Hostname | Changes hostname |
Device name | 71 | 72 | Device name | Changes device name |
Digital output 1 (DOUT1) (ON/OFF*) | 201 | 202 | 1 | 0 | Changes the state of the open collector (OC) output |
Digital output 2 (DOUT2) (ON/OFF*) | 202 | 203 | 1 | 0 | Changes the state of the relay output |
Switch WiFi (ON/OFF*) | 203 | 204 | 1 | 0 | Turns WiFi ON or OFF |
Switch mobile data connection (ON/OFF*) | 204 | 205 | 1 | 0 | Turns mobile data connection ON or OFF |
Switch SIM card | 205 | 206 | 1 | 2 | 0 | Changes the active SIM card slot
|
Reboot | 206 | 207 | 1 | Reboots the router |
Change APN | 207 | 208 | APN code | Changes APN. The number of input registers may vary depending on the length of the APN, but the very first byte of the set APN command denotes the number of the SIM card for which to set the APN. This byte should be set to:
|
Switch PIN4 state (ON/OFF*) | 325 | 326 | 1 | 0 | Turns PIN4 state ON or OFF |