TSW010 Power Consumption

From Teltonika Networks Wiki
Revision as of 08:42, 14 November 2022 by Paulius R (talk | contribs) (Created page with "TSW010 power consumption values in different states of operation are represented in the table(s) below:<br><br> <table class="nd-othertables_3"> <tr style="font-weight:bol...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > TSW Switches > TSW010 > TSW010 Manual > TSW010 Power Consumption

TSW010 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
25
0.23
Idle (24 V)
21
0.26
Idle (24 V)
14
0.33


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
49
0.45
2 LAN devices connected + heavy data traffic1 (12 V)
39
0.47
2 LAN devices connected + heavy data traffic1 (24 V)
24
0.58


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
78
0.70
5 LAN devices connected + heavy data traffic1 (12 V)
61
0.73
5 LAN devices connected + heavy data traffic1 (24 V)
37
0.89


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.