Summary

The Data to Server feature provides you with the possibility to set up data senders that collect data from various sources and periodically send it to remote servers.

Note: On RUT360, Data to Server is additional software that can be installed from the System → Package Manager page.

If you're having trouble finding this page or some of the parameters described here on your device's WebUI, you should turn on "Advanced WebUI" mode. You can do that by clicking the "Advanced" button, located at the top of the WebUI.

Networking rutos manual webui basic advanced mode 75.gif

Data Senders

A Data Sender is an instance that gathers and periodically sends collected data to a specified server. The Data Senders list is empty by default so, in order to begin configuration you must add a new data sender first. To add a new data sender, click the 'Add' button.

Networking rutos manual data to server data senders add button v3.png

After this you should be redirected to the newly added data sender's configuration page.

Sender Settings


Refer to the table below for descriptions on data sender configuration fields.

Note: these tables have coloring schemes to indicate which fields can be seen with different configuration.

Networking rutos manual data to server data configuration.png

Data configuration

Field Value Description
Name string; default: none Name of the data sender. Used for easier data senders management purposes only (optional).
Type ModbusModbus alarms* | WiFi scanner data* | DNP3* | DNP3 data flash*; default: Modbus data Source of the data to be sent to server.
Format type Json, custom; default: Json Arranges the format of the sent segment.
JSON format string; default: {"TS": "%t", "D": "%d", "data": %a} Arranges the format of the sent JSON segment.
Segment count integer [1..10]; default: 1 Max segment count in one JSON string sent to server.
Send as object off | on; default: off When turned on, sends JSON segment as object and not as an array element.
Data filtering All data | By slave ID | By slave IP; default: All data If Data source: Modbus data. Choose which data this sender will send to server.
By slave ID: Slave ID integer [1..255]; default: none ID of the Modbus slave whose collected data will be sent to server.
By slave IP: Slave IP ip; default: none IP address of the Modbus slave whose collected data will be sent to server (for Modbus TCP slaves).
Data filtering All data | DNP3 Address | DNP3 IP; default: All data If Data source: DNP3. Choose which data this sender will send to server.
DNP3 Address: DNP3 Address integer [0..65519]; default: none DNP3 address of device whose collected data will be sent to server.
DNP3 IP: DNP3 IP ip | domain; default: none IP address of DNP3 device whose collected data will be sent to server.
Retry on fail off | on; default: off When turned on, the data sender retries failed sending attempts until the are successfully delivered.


Collection general settings


Networking rutos manual data to server collection configuration general settings.png

Field Value Description
Enable on, off; default: on Enables instance.
Type Json, custom; default: Json Data input type.
Json string; default: {"TS": "%t", "D": "%d", "data": %a} Arranges the format of the sent JSON segment.
custom string; default: empty Type of data formatting.
Empty value string; default: N/A A string which will be placed if any value cannot be received.

Collection advanced settings


Networking rutos manual data to server collection configuration advanced settings.png

Field Value Description
Period integer [1..86400]; default: 60 Data sending frequency (in seconds).
Retry off | on; default: off When turned on, the data sender retries failed sending attempts until the are successfully delivered.
Retry count integer [1..10]; default: 10 Retry to send the same data N times.
Timeout integer [1..60]; default: 1 Timeout in second between retry attempts.

Server configuration


Networking rutos manual data to server server configuration.png

Field Value Description
Protocol HTTP(S) | MQTT* | Kinesis; default: HTTP(S) Protocol used for sending the data to server.
Server address string; default: none URL for HTTP(S); Host for MQTT; Connection string for Azure MQTT.
HTTP Header string; default: none Allows to add custom headers to the HTTP requests.
Enable secure connection on, off; default: off Enables use of TLS certificates
Certificate files from device on, off; default: off Choose this option if you want to select certificate files from device.
Certificate based: CA File .ca file; default: none Certificate authority is an entity that issues digital certificates. A digital certificate certifies the ownership of a public key by the named subject of the certificate.
Certificate based: Client Certificate .crt file; default: none Certificate file is a type of digital certificate that is used by client systems to make authenticated requests to a remote server. If client certificate is not needed, leave both client certificate and client key fields empty.
Certificate based: Private Key .key file; default: none File containing private key for this client. This file needs to be not encrypted.

* This is additional software that can be installed from the System → Package Manager page.