Changes

8,218 bytes removed ,  14:46, 6 December 2022
no edit summary
Line 1: Line 1: −
{{Template: Networking_rutxxx_manual_input_output
+
{{Template: Networking_rutos_manual_input_output
<!----------------------------DEVICE DETAILS---------------------------->
+
<!------------------------DEVICE----------------------->
| name                 = RUT955
+
| name           = RUT955
| fw_version            = RUT9XX_R_00.06.04
+
| series        = RUT9
<!--------------------------------STATUS-------------------------------->
+
<!----------------------SEPARATORS--------------------->
| file_status          = Networking_rut955_manual_input_output_status_io_status_v1.png
+
| analog        = 1    <!-- 0 - doesn't have Analog Input; 1 - has Analog Input -->
| file_status_digital  = Networking_rutxxx_manual_input_output_status_custom_label_digital_input_v1.png
+
| configurableio = 0    <!-- 0 - doesn't have Configurable I/O; 1 - has Configurable I/O -->
| file_status_analog    = Networking_rut955_manual_input_output_status_custom_label_analog_input_v1.png
+
| dualsim       = 1     <!-- 0 - doesn't have Dual SIM; 1 - has Dual SIM -->
<!--------------------------------INPUT--------------------------------->
+
| input_volts    = 9-30  <!-- Input voltage range -->
| file_input_analog    = Networking_rut955_manual_input_output_input_check_analog_v1.png
+
| juggler_input  = 0    <!-- first input on the I/O Juggler list. 0 - Input; 1 - Configurable I/O; 2 - Passive/Active Input -->
| file_input_add       = Networking_rutxxx_manual_input_output_input_input_rules_add_new_v1.png
+
| mobile        = 1    <!-- 0 - doesn't have mobile; 1 - has mobile -->
| file_input_config     = Networking_rut955_manual_input_output_input_input_rules_input_configuration_v1.png
+
| wifi          = 1    <!-- 0 - doesn't have wifi; 1 - has wifi -->
<!--------------------------------OUTPUT-------------------------------->
+
| acl            = 1    <!-- 0 - doesn't have Analog Current Loop; 1 - has Analog Current Loop -->
| file_output_config    = Networking_rut955_manual_input_output_output_output_configuration_v1.png
  −
| file_output_on_off    = Networking_rut955_manual_input_output_output_on_off_v1.png
  −
| file_output_post_get  = Networking_rutxxx_manual_input_output_output_post_get_configuration_v1.png
  −
| file_output_periodic  = Networking_rut955_manual_input_output_output_periodic_control_v1.png
  −
| file_output_scheduler = Networking_rut955_manual_input_output_output_scheduler_v1.png
   
}}
 
}}
  −
==Output==
  −
  −
The '''Output''' section is used to configure the router's outputs: '''Relay''' Output and '''Open Collector''' ('''OC''') Output.
  −
  −
===Output Configuration===
  −
----
  −
The '''Output Configuration''' tab is used to change the default states of the router's outputs.
  −
  −
[[File:Services inputoutput output configuration v2.png]]
  −
  −
<table class="nd-mantable">
  −
    <tr>
  −
        <th>field name</th>
  −
      <th>value</th>
  −
      <th>description</th>
  −
    </tr>
  −
    <tr>
  −
      <td>Open collector output</td>
  −
      <td>High level | Low level; Default: '''Low level'''</td>
  −
      <td>Changes the default<span style="color:#0054A6;">'''*'''</span> state of the Open collector (OC) output</td>
  −
    </tr>
  −
    <tr>
  −
      <td>Relay output</td>
  −
      <td>Contacts open | Contacts closed; Default: '''Contacts closed'''</td>
  −
      <td>Relay Output default state</td>
  −
    </tr>
  −
</table>
  −
  −
<span style="color:#0054A6;">'''*'''</span> Changing the default state of an output means that the changes will be written into the input/output config and saved, therefore making the change permanent. This means that, unless some other related change occurs, the state of the output will remain as set in this section. Therefore, if the input/output service restarts or the device reboots, it will have no effect on the state of the output.
  −
  −
===ON/OFF===
  −
----
  −
The '''ON/OFF''' section is used to turn Outputs ON or OFF, but it doesn't save the state permanently, meaning that after a reboot the states will revert back to their default values.
  −
  −
[[File:Services inputoutput output onoff v2.png]]
  −
  −
===Post/Get Configuration===
  −
----
  −
'''Post/Get Configuration''' allows you to perform action requests by writing them in the URL field after your device’s IP address.
  −
  −
[[File:Services inputoutput output post get v2.png]]
  −
  −
<table class="nd-mantable">
  −
    <tr>
  −
        <th>field name</th>
  −
      <th>value</th>
  −
      <th>description</th>
  −
    </tr>
  −
    <tr>
  −
      <td>Enable</td>
  −
      <td>yes | no; Default: '''no'''</td>
  −
      <td>Toggles POST/GET ON or OFF</td>
  −
    </tr>
  −
    <tr>
  −
      <td>Username</td>
  −
      <td>string; Default: " "</td>
  −
      <td>Username used for authentication in POST/GET queries</td>
  −
    </tr>
  −
    <tr>
  −
    <td>Password</td>
  −
        <td>string; Default: " "</td>
  −
        <td>Password used for authentication in POST/GET queries</td>
  −
    </tr>
  −
</table>
  −
  −
====Post/Get usage====
  −
----
  −
{{Template: webui_services_input_output_post_get_configuration_usage}}
  −
  −
<table class="nd-othertables">
  −
    <tr>
  −
        <th style="width: 500px">ACTION</th>
  −
      <th style="width: 900px">POST/GET URL EXAMPLE</th>
  −
    </tr>
  −
    <tr>
  −
      <td>Turn Relay Output ON</td>
  −
      <td>http://192.168.1.1/cgi-bin/output?username=user1&password=user1&action=on&pin=relay</td>
  −
    </tr>
  −
    <tr>
  −
      <td>Turn Relay Output ON after a 10 second delay</td>
  −
      <td>http://192.168.1.1/cgi-bin/output?username=user1&password=user1&action=on&pin=relay&delay=10</td>
  −
    </tr>
  −
    <tr>
  −
    <td>Turn Relay Output ON for 5 seconds</td>
  −
        <td>http://192.168.1.1/cgi-bin/output?username=user1&password=user1&action=on&pin=relay&time=5</td>
  −
    </tr>
  −
    <tr>
  −
    <td>Turn Relay Output ON for 5 seconds after a 15 second delay</td>
  −
        <td>http://192.168.1.1/cgi-bin/output?username=user1&password=user1&action=on&pin=relay&delay=15&time=5</td>
  −
    </tr>
  −
    <tr>
  −
      <td>Turn Relay Output OFF for 5 seconds after a 15 second delay</td>
  −
      <td>http://192.168.1.1/cgi-bin/output?username=user1&password=user1&action=off&pin=relay&delay=15&time=5</td>
  −
    </tr>
  −
    <tr>
  −
    <td>Turn Open Collector Output ON</td>
  −
        <td>http://192.168.1.1/cgi-bin/output?username=user1&password=user1&action=on&pin=oc</td>
  −
    </tr>
  −
    <tr>
  −
    <td>Turn Open Collector Output OFF</td>
  −
        <td>http://192.168.1.1/cgi-bin/output?username=user1&password=user1&action=off&pin=oc</td>
  −
    </tr>
  −
</table>
  −
  −
'''Overview''':
  −
* '''192.168.1.1''' - router's default LAN IP address; replace it in accordance with your own configuration
  −
* '''username''' - login name from Post/Get Configuration
  −
* '''password''' - password from Post/Get Configuration
  −
* '''action''' - the action that is to be performed on the specified Output (can be '''on''' or '''off''')
  −
* '''pin''' - specifies on which Output the action will be applied (can be '''oc''' or '''relay''')
  −
* '''delay''' - defines a delay (in seconds) after which the specified action will be performed
  −
* '''time''' - defines a window of time during which the action will take place. For instance, if you post an ON action for an output while specifying '''time=5''', that Output will turn ON and stay ON for 5 seconds before turning OFF
  −
  −
Delay and time parameters can be used together. For example, if delay is 10, time is 5, action is on, then 10 seconds after the execution of the command, the output will switch to ON (or stay in ON state if it was already ON), then after 5 more seconds it will switch to OFF state. In this case, the overall command execution time is 15 seconds.
  −
  −
Actions ON and OFF depend on setting „Output configuration in active state“ (ON is active state), which can be set via [[Input/Output#Output|Services → Input/Output → Output]]
  −
  −
===Periodic Control===
  −
----
  −
The '''Periodic control''' section allows you to set up automatic output control rules that trigger output state changes at the specified period or interval.
  −
  −
[[File:Services inputoutput output periodic v2.png]]
  −
  −
<table class="nd-mantable">
  −
    <tr>
  −
        <th>field name</th>
  −
      <th>value</th>
  −
      <th>description</th>
  −
    </tr>
  −
    <tr>
  −
      <td>Enable</td>
  −
      <td>yes | no; Default: '''no'''</td>
  −
      <td>Toggles the rule ON or OFF</td>
  −
    </tr>
  −
    <tr>
  −
      <td>Output</td>
  −
      <td>Digital OC output | Digital Relay output; Default: '''Digital OC output'''</td>
  −
      <td>To which output the rule pertains </td>
  −
    </tr>
  −
    <tr>
  −
    <td>Action</td>
  −
        <td>On | Off; Default: '''On'''</td>
  −
        <td>Periodic action to be taken</td>
  −
    </tr>
  −
    <tr>
  −
    <td>Action timeout</td>
  −
        <td>yes | no; Default: '''no'''</td>
  −
        <td>Activates action timeout. Action timeout specifies whether an action should end after some time. For example, if the specified Action is to turn Digital OC output On and the action triggers, the Action timeout then turns Digital OC output back off after a specified amount of time in seconds specified in this field </td>
  −
    </tr>
  −
    <tr>
  −
    <td>Timeout (sec)</td>
  −
        <td>integer; Default: " "</td>
  −
        <td>Specifies how long the Action timeout is</td>
  −
    </tr>
  −
    <tr>
  −
    <td>Mode</td>
  −
        <td>Fixed | Interval; Default: '''Fixed'''</td>
  −
        <td>'''Fixed''' mode triggers the specified action on a specified day(s), hour and minute. For example, every Sunday at 8:30 AM<br>
  −
  −
'''Interval''' provides you with the possibility to set up an interval after which the same action takes place</td>
  −
    </tr>
  −
</table>
  −
  −
===Scheduler===
  −
----
  −
The '''Scheduler''' lets you configure a schedule of when certain outputs are to be enabled or disabled.
  −
  −
[[File:Services inputoutput output scheduler v2.png]]
  −
  −
==Additional Information==
  −
  −
* Input/Output hardware application examples:
  −
** '''[[RUT955 Connecting relay to open collector output|Connecting relay to open collector output]]'''
  −
** '''[[Inverting RUT955 relay output polarity|Inverting relay output polarity]]'''
  −
** '''[[Using RUT955 Inputs for security applications|Using Inputs for security applications]]'''
  −
** '''[[Current measurement with RUT955 analog input|Current measurement with analog input]]'''
  −
  −
[[Category:RUT955 WebUI]]
 

Navigation menu