Changes

no edit summary
Line 38: Line 38:  
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Protocol</td>
+
         <td>IP family</td>
         <td>UDP | TCP; default: '''UDP'''</td>
+
         <td>IPv4 | IPv6 | IPv4v6; default: '''IPv4'''</td>
         <td>SNMP service's protocol.</td>
+
         <td>IP family used by SNMP.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
Line 207: Line 207:  
         <td>ip; default: <b>none</b></td>
 
         <td>ip; default: <b>none</b></td>
 
         <td>Netmask for IP of the community.</td>
 
         <td>Netmask for IP of the community.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Access Mode</td>
 +
        <td>Read-Only | Read-Write; default: <b>Read-Only</b></td>
 +
        <td>Access mode for current community.</td>
 +
    </tr>
 +
</table>
 +
 +
SNMPv6 community configuration page:
 +
 +
[[File:Networking_rutos_manual_snmp_communities_snmpv6_community_configuration.png|border|class=tlt-border]]
 +
 +
<table class="nd-mantable">
 +
    <tr>
 +
        <th>Field</th>
 +
        <th>Value</th>
 +
        <th>Description</th>
 +
    </tr>
 +
    <tr>
 +
        <td>Community name</td>
 +
        <td>string; default: <b>none</b></td>
 +
        <td>Name of the community.</td>
 +
    </tr>
 +
    <tr>
 +
        <td>Source</td>
 +
        <td>ip6 | domain name; default: <b>default</b></td>
 +
        <td>Source of the community.</td>
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
Line 273: Line 300:     
[[File:Networking_rutos_manual_snmp_trap_settings_trap_rules_add_button.png|border|class=tlt-border]]
 
[[File:Networking_rutos_manual_snmp_trap_settings_trap_rules_add_button.png|border|class=tlt-border]]
  −
You can then edit the trap rule by clicking the 'Edit' button next to it.
  −
  −
[[File:Networking_rutos_manual_snmp_trap_settings_trap_rules_edit_button.png|border|class=tlt-border]]
      
You should be redirected to the rule's configuration page which should look something like this:
 
You should be redirected to the rule's configuration page which should look something like this:
Line 359: Line 382:  
     <tr>
 
     <tr>
 
         <td>Input/Output name</td>
 
         <td>Input/Output name</td>
         <td>Input(3) {{!}} Output(4); default: <b>Input(3)</b></td>
+
         <td>Output(4) {{!}} Input(3); default: <b>Output(4)</b></td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
         <td>Which type of Inputs and Outputs to use in this rule.</td>
 
     </tr>
 
     </tr>
Line 465: Line 488:  
             <td>Active {{!}} Inactive {{!}} Both; default: <b>Active</b></td>
 
             <td>Active {{!}} Inactive {{!}} Both; default: <b>Active</b></td>
 
             <td>On which Input/Output state will this rule be triggered.</td>
 
             <td>On which Input/Output state will this rule be triggered.</td>
 +
        </tr>}}
 +
|RUT36X =
 +
        <tr>
 +
            <td>Input/Output type</td>
 +
            <td>Input/Output; default: <b>Input/Output</b></td>
 +
            <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
        </tr>
 +
        <tr>
 +
            <td>Input/Output name</td>
 +
            <td>Input(3) {{!}} Output(4); default: <b>Input(3)</b></td>
 +
            <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
        </tr>
 +
        <tr>
 +
            <td>State change</td>
 +
            <td>Active {{!}} Inactive {{!}} Both; default: <b>Active</b></td>
 +
            <td>On which Input/Output state will this rule be triggered.</td>
 +
        </tr>
 +
|RUT9 =
 +
    {{#ifeq:{{{name}}}|RUT955|
 +
        <tr>
 +
            <td>Input/Output type</td>
 +
            <td><span style="color:blue">Input/Output</span> {{!}} <span style="color:forestgreen"><b>Relay</b></span> {{!}} <span style="color:darkred"><b>4–20 mA Current Loop</b></span> {{!}} <span style="color:chocolate">ADC</span>; default: <b>Input/Output</b></td>
 +
            <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
        </tr>
 +
        <tr>
 +
            <td><span style="color:blue">Input/Output:</span> Input/Output name</td>
 +
            <td>Input (3) {{!}} Input (1) {{!}} Output(4) {{!}} Isolated Output (3,4,8) {{!}} Isolate Input (2,7); default: <b>Input (3)</b></td>
 +
            <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
        </tr>
 +
        <tr>
 +
            <td><span style="color:blue">Input/Output:</span> State change</td>
 +
            <td>Active {{!}} Inactive {{!}} Both; default: <b>Active</b></td>
 +
            <td>On which Input/Output state will this rule be triggered.</td>
 +
        </tr>
 +
        <tr>
 +
            <td><span style="color:forestgreen">Relay:</span> Input/Output name</td>
 +
            <td>Relay(5,10); default: <b>Relay(5,10)</b></td>
 +
            <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
        </tr>
 +
        <tr>
 +
            <td><span style="color:forestgreen">Relay:</span> State change</td>
 +
            <td>Open {{!}} Closed {{!}} Both; default: <b>Open</b></td>
 +
            <td>On which Input/Output state will this rule be triggered.</td>
 +
        </tr>
 +
        <tr>
 +
            <td><span style="color:darkred">4–20 mA Current Loop:</span> Input/Output name</td>
 +
            <td>Analog Current Loop (6,9); default: <b>Analog Current Loop (6,9)</b></td>
 +
            <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
        </tr>
 +
        <tr>
 +
            <td><span style="color:darkred">4–20 mA Current Loop:</span> Voltage</td>
 +
            <td>positive float [0..40]; default: <b>none</b></td>
 +
            <td>At which voltage value will this rule be triggered.</td>
 +
        </tr>
 +
        <tr>
 +
            <td><span style="color:chocolate">ADC:</span> Input/Output name</td>
 +
            <td>Analog Input (6,9); default: <b>Analog Input (6,9)</b></td>
 +
            <td>Which type of Inputs and Outputs to use in this rule.</td>
 +
        </tr>
 +
        <tr>
 +
            <td><span style="color:chocolate">ADC:</span> Voltage</td>
 +
            <td>positive float [0..40]; default: <b>none</b></td>
 +
            <td>At which voltage value will this rule be triggered.</td>
 
         </tr>
 
         </tr>
|RUT3 =
+
    |
 
         <tr>
 
         <tr>
 
             <td>Input/Output type</td>
 
             <td>Input/Output type</td>
Line 481: Line 567:  
             <td>Active {{!}} Inactive {{!}} Both; default: <b>Active</b></td>
 
             <td>Active {{!}} Inactive {{!}} Both; default: <b>Active</b></td>
 
             <td>On which Input/Output state will this rule be triggered.</td>
 
             <td>On which Input/Output state will this rule be triggered.</td>
         </tr>
+
         </tr>}}
 
     |}}
 
     |}}
 
}}
 
}}