TSF010 Power Consumption

From Teltonika Networks Wiki
Main Page > TSF Switches > TSF010 > TSF010 Manual > TSF010 Power Consumption

TSF010 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
24
0.22
Idle (12 V)
19
0.23
Idle (24 V)
11
0.26
Idle (44 V)
11
0.48
Idle (50 V)
11
0.55
Idle (57 V)
11
0.63


Test type
Current (mA)
Power consumption (W)
Idle, 2 LAN device connected (9 V)
49
0.44
Idle, 2 LAN device connected (12 V)
38
0.46
Idle, 2 LAN device connected (24 V)
21
0.5
Idle, 2 LAN device connected (44 V)
17
0.75
Idle, 2 LAN device connected (50 V)
16
0.8
Idle, 2 LAN device connected (57 V)
15
0.86


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
48
0.432
2 LAN devices connected + heavy data traffic1 (12 V)
37
0.44
2 LAN devices connected + heavy data traffic1 (24 V)
21
0.5
2 LAN devices connected + heavy data traffic1 (44 V)
18
0.79
2 LAN devices connected + heavy data traffic1 (50 V)
16
0.8
2 LAN devices connected + heavy data traffic1 (57 V)
15
0.86


Test type
Current (mA)
Power consumption (W)
Idle, 5 LAN device connected (9 V)
85
0.77
Idle, 5 LAN device connected (12 V)
66
0.79
Idle, 5 LAN device connected (24 V)
37
0.89
Idle, 5 LAN device connected (44 V)
26
1.14
Idle, 5 LAN device connected (50 V)
24
1.2
Idle, 5 LAN device connected (57 V)
23
1.31


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
82
0.74
5 LAN devices connected + heavy data traffic1 (12 V)
64
0.77
5 LAN devices connected + heavy data traffic1 (24 V)
36
0.86
5 LAN devices connected + heavy data traffic1 (44 V)
26
1.14
5 LAN devices connected + heavy data traffic1 (50 V)
24
1.2
5 LAN devices connected + heavy data traffic1 (57 V)
22
1.25


Test type
Current (mA)
Power consumption (W)
4 PoE dummy loads connected (30 W each), 5 LAN devices connected + heavy data traffic1 (54 V)
2186
118


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to connected devices, testing environment and conditions.