TSW110 Power Consumption

From Teltonika Networks Wiki
Revision as of 07:13, 8 October 2020 by Dziugas (talk | contribs) (Created page with "{{Template: Networking_device_faq_power_consumption | name = TSW110 }}")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > TSW Switches > TSW110 > TSW110 Manual > TSW110 Power Consumption

TSW110 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
26
0.23
Idle (12 V)
20
0.24
Idle (24 V)
11
0.26


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
72
0.65
2 LAN devices connected + heavy data traffic1 (12 V)
56
0.67
2 LAN devices connected + heavy data traffic1 (24 V)
31
0.74


Test type
Current (mA)
Power consumption (W)
3 LAN devices connected + heavy data traffic1 (9 V)
84
0.76
3 LAN devices connected + heavy data traffic1 (12 V)
63
0.76
3 LAN devices connected + heavy data traffic1 (24 V)
35
0.84


Test type
Current (mA)
Power consumption (W)
4 LAN devices connected + heavy data traffic1 (9 V)
120
1.08
4 LAN devices connected + heavy data traffic1 (12 V)
91
1.10
4 LAN devices connected + heavy data traffic1 (24 V)
48
1.15


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
155
1.40
5 LAN devices connected + heavy data traffic1 (12 V)
118
1.42
5 LAN devices connected + heavy data traffic1 (24 V)
62
1.49


1 - Data streams between devices were created using iPerf.
Power consumption may differ due to testing environment and conditions.