Difference between revisions of "TSW114 Power Consumption"

From Teltonika Networks Wiki
(Created page with "TSW114 power consumption values in different states of operation are represented in the table(s) below:<br><br> <table class="nd-othertables_3"> <tr style="font-weight:bol...")
 
 
(One intermediate revision by one other user not shown)
Line 12: Line 12:
 
     </tr>
 
     </tr>
 
     <tr>
 
     <tr>
         <td>Idle (24 V)</td>
+
         <td>Idle (12 V)</td>
 
       <td><center><b>21</b></td>
 
       <td><center><b>21</b></td>
 
       <td><center><b>0.25</b></td>
 
       <td><center><b>0.25</b></td>

Latest revision as of 11:31, 8 April 2024

Main Page > TSW Switches > TSW114 > TSW114 Manual > TSW114 Power Consumption

TSW114 power consumption values in different states of operation are represented in the table(s) below:

Test type
Current (mA)
Power consumption (W)
Idle (9 V)
26
0.24
Idle (12 V)
21
0.25
Idle (24 V)
12
0.30


Test type
Current (mA)
Power consumption (W)
2 LAN devices connected + heavy data traffic1 (9 V)
99
0.86
2 LAN devices connected + heavy data traffic1 (12 V)
74
0.89
2 LAN devices connected + heavy data traffic1 (24 V)
43
1.03


Test type
Current (mA)
Power consumption (W)
5 LAN devices connected + heavy data traffic1 (9 V)
204
1.84
5 LAN devices connected + heavy data traffic1 (12 V)
154
1.85
5 LAN devices connected + heavy data traffic1 (24 V)
86
2.07


1 - Data streams between devices were created using iPerf.