Template:Networking rut2xx manual modbus modbus tcp table

Revision as of 10:48, 4 December 2018 by Dziugas (talk | contribs) (Created page with "<table class="nd-mantable"> <tr> <th>field name</th> <th>value</th> <th>description</th> </tr> <tr> <td>Enable</td> <td>yes...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
field name value description
Enable yes | no; Default: none Toggles Modbus TCP ON or OFF
Port integer [0..65535]; Default: none Specifies which port will be used for Modbus communication
Allow Remote Access yes | no; Default: no Allows remote Modbus connections by adding an exception to the device's firewall on the port specified in the field above
Mobile Traffic Usage Logging yes | no; Default: no Enables Mobile Traffic Usage Logging (can also be enabled from Status → Mobile Traffic → Configuration).
This is required in order to read mobile data usage information from Modbus registers