Revision as of 17:41, 6 December 2018
required value | register number | number of registers | representation |
---|---|---|---|
System uptime | 1 | 2 | 32 bit unsigned integer |
Mobile signal strength (RSSI in dBm) | 3 | 2 | 32 bit integer |
System temperature (in 0.1 °C) | 5 | 2 | 32 bit integer |
System hostname | 7 | 16 | Text |
GSM operator name | 23 | 16 | Text |
Router serial number | 39 | 16 | Text |
LAN MAC address | 55 | 16 | Text |
Router name | 71 | 16 | Text |
Currently active SIM card slot | 87 | 16 | Text |
Network registration info | 103 | 16 | Text |
Network type | 119 | 16 | Text |
Current WAN IP address | 139 | 16 | 32 bit unsigned integer |